13.3 Special Soldering Point Soldering Operation
13.3.1 Soldering Operation by I/O Port
Refer to “13.1.1 Soldering Operation by I/O Port” about timing chart and timing.
Soldering operation is as following.
1. It controls the temperature to 2nd temperature control setting temperature or setting
temperature.
2. It feeds solder wire in accordance with 1st solder amount / speed setting.
3. It reverses solder wire in accordance with 1st solder amount / speed setting.
4. It lowers the iron.
5. It waits according to pre-heat time.
6. It feeds solder wire in accordance with 2nd solder amount / speed setting.
7. It reverses solder wire in accordance with 2nd solder amount / speed setting.
8. It waits according to heat time setting.
9. It feeds solder wire in accordance with 3rd solder amount / speed setting.
10. It reverses solder wire in accordance with 3rd solder amount / speed setting.
11. It rises the iron.
12. It controls the temperature to the setting temperature or wait temperature setting.
(When wait time is set, it controls the temperature after the wait time passed.)
3rd Solder Reversing
K Command
3rd Solder Feeding
Iron Up