EasyManua.ls Logo

Apollo Seiko OMEGA - 13.4 Special Soldering Slide Soldering Operation

Apollo Seiko OMEGA
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
25 / 60
13.4 Special Soldering Slide Soldering Operation
13.4.1 Soldering Operation by I/O Port
Refer to “13.2.1 Soldering Operation by I/O Port” for details of timing chart and timing.
Soldering operation is as following.
1. It controls the temperature to 2nd temperature control setting temperature or setting
temperature.
2. It feeds solder wire in accordance with 1st solder amount / speed setting.
3. It reverses solder wire in accordance with 1st solder amount / speed setting.
4. It lowers the iron.
5. It waits according to pre-heat time setting.
6. Solder pool time starts. When it is completed, ACK is outputted as a pulse.
It feeds solder wire in accordance with 2nd solder amount / speed setting.
*When and start at the same time and both of them complete, it is shifted to 2nd solder
reversing.
(If Solder pool time is more longer, when is completed, it stops feeding solder wire and it
waits until is completed.)
7. It feeds solder wire in accordance with 2nd solder amount / speed setting.
8. It reverses solder wire in accordance with 2nd solder amount / speed setting.
9. It waits according to heat time setting.
10. It feeds solder wire in accordance with 3rd solder amount / speed setting.
11. It reverses solder wire in accordance with 3rd solder amount / speed setting.
12. It rises the iron.
13. It controls the temperature to the setting temperature or wait temperature setting.
(When wait time is set, it controls the temperature after the wait time passed.)