13.2 Slide Soldering Operation
13.2.1 Soldering Operation by I/O Port
1. Specify a solder condition number by SEL1, SEL2, SEL4, SEL8, SEL16, SEL32, SEL64,
SEL100 and SEL200.
2. Start the soldering operation by START signal. (Delay of more than 100msec is necessary from
solder condition number specification)
3. When it receives START signal, READY signal becomes LOW.
4. When it receives START signal, RUNNING signal becomes High.
5. It prepares to solder.
6. When soldering preparation is completed, ACK is outputted as a pulse.
7. It starts to solder.
8. When soldering is completed, COUNTER OUT is outputted as a pulse.
9. After COUNTER OUT is outputted as a pulse, END is outputted as a pulse.
10. After COUNTER OUT is outputted as a pulse, READY signal becomes High.
11. After COUNTER OUT is outputted as a pulse, RUNNING signal becomes LOW.
* It is not necessary that START signal is outputted as a pulse. (Except for LAN operation)
The soldering preparation is as following.
1. It controls the temperature to 2nd temperature control setting temperature or setting
temperature.
2. It feeds solder wire in accordance with 1st solder amount / speed setting.
3. It reverses solder wire in accordance with 1st solder amount / speed setting.
4. It lowers the iron.
5. It waits according to pre-heat time.