13.9.2 Soldering Operation by Serial Communication port
It needs to set a suitable WK No. in Solder condition setting in advance.
If it executes cleaning at the position that the iron is lowered, the iron moves upwards after cleaning
is completed.
If it executes cleaning at the position that the iron is risen, the iron remains raised after cleaning is
completed.
Robot
Board
H Command
Air blow ON
h Command
Iron Up or
DownPre-
heating Time
Waiting
Air blow time waiting
Air blow OFF
Waiting Time after air
blow
Waiting
Iron Up or Waiting