Solarpaint
AL1206 Installation Manual
14.9.2023
Rev. [B1]
Page 9 of 28
Wiring and connections
1. General information
a. The AL1206 module is wired with PV grade 4[mm²] cables with corresponding 1500V rated
MC4-EVO2 connectors.
b. DC string extensions and field wiring using IEC 62930 PV grade, UV and temperature
resistant, flame retardant 6[mm²] wire, or larger diameter.
c. Each module contains 3 units of 25A bypass diodes located inside the Junction box
2. Series connection
NOTE: Modules with different characteristics must not be connected in series
3. Parallel connection