22
8.2 Measurement Characteristics
(All at 23°C ± 5°C ,< 80% R.H.) ±([% of reading] + [number of least digits]).
Functions with 4000-count mode divide the [ number of least digits ] by 10 when on
4000 count mode, in addition DCV to add 2 more digits on every ranges.
1. VOLTAGE :
DCV 107N 109N
20mV
± (0.06% + 60) ± (0.06% + 60)
200mV
± (0.06% + 20) ± (0.06% + 20)
2V, 20V, 200V, 1000V
± (0.06% + 10) ± (0.06% + 10)
ACV 107N
109N
20mV,200mV
40Hz ~ 100Hz
100Hz ~ 1KHz
± (0.70% + 80)
± (1.00% + 80)
± (0.70% + 80)
± (1.00% + 80)
2V
40Hz ~ 100Hz
100Hz ~ 1KHz
1KHz ~ 10KHz
10KHz ~ 20KHz
20KHz ~ 50KHz
50KHz ~ 100KHz
± (0.70% + 50)
± (1.00% + 50)
± (2.00% + 60)
± (3.00% + 70)
± (5.00% + 80)
± (10.00% + 100)
± (0.70% + 50)
± (1.00% + 50)
± (2.00% + 60)
± (3.00% + 70)
± (5.00% + 80)
± (10.00% + 100)
20V
40Hz ~ 100Hz
100Hz ~ 1KHz
1KHz ~ 10KHz
10KHz ~ 20KHz
20KHz ~ 50KHz
50KHz ~ 100KHz
± (0.70% + 50)
± (1.00% + 50)
± (2.00% + 60)
± (3.00% + 70)
± (5.00% + 80)
± (10.00% + 100)
± (0.70% + 50)
± (1.00% + 50)
± (2.00% + 60)
± (3.00% + 70)
± (5.00% + 80)
± (10.00% + 100)
200V
40Hz ~ 100Hz
100Hz ~ 1KHz
1KHz ~ 10KHz
10KHz ~ 20KHz
20KHz ~ 50KHz
± (0.70% + 50)
± (1.00% + 50)
± (2.00% + 60)
± (3.00% + 70)
± (5.00% + 80)
± (0.70% + 50)
± (1.00% + 50)
± (2.00% + 60)
± (3.00% + 70)
± (5.00% + 80)
750V
40Hz ~ 100Hz
100Hz ~ 1KHz
± (0.70% + 50)
± (1.00% + 50)
± (0.70% + 50)
± (1.00% + 50)
Bandwidth
40Hz ~ 100KHz 40Hz ~ 100KHz