8.1 DS3 series Microinverter Datasheet
Model
DS3-S
DS3-L
DS3
DS3-H
Region
Australia, New Zealand
Input Data (DC)
Operating Voltage Range
16V-60V
Maximum Input Voltage
60V
Maximum Input Current
18A x 2
18A x 2
20A x 2
20A x 2
ISC PV
22.5A x 2
22.5A x 2
25A x 2
25A x 2
Output Data (AC)
Rated Apparent Power
625VA
750VA
880VA
960VA
Nominal Output Voltage/Range
(1)
230V / 180V-258V
Rated Current
2.7A
3.3A
3.8A
4.2A
Nominal Output Frequency/ Range
(1)
50Hz/47Hz-52Hz
Power Factor (Default/Adjustable)
0.99/0.8 leading…0.8 lagging
Maximum Units per 2.5mm² Branch
(2)
8
6
6
5
Maximum Units per 4mm² Branch
(2)
10
8
7
6
Efficiency
Peak Efficiency
97.3%
CEC Efficiency
97%
Nominal MPPT Efficiency
99.5%
Night Power Consumption
20mW
Mechanical Data
Operating Ambient Temperature Range
(3)
- 40 °C to + 65 °C
Storage Temperature Range
- 40 °C to + 85 °C
Dimensions (W x H x D)
263mm x 218mm x 41.2mm
263mm x 218mm x 42.5mm
Weight
2.7kg
3.1kg
AC Bus Cable
2.5mm
2
(23A)/4mm
2
(28A)
DC Connector Type
Stäubli MC4 PV-ADBP4-S2&ADSP4-S2
Cooling
Natural Convection - No Fans
Enclosure Environmental Rating
IP67
Features
Communication (Inverter To ECU)
(4)
Encrypted ZigBee
Isolation Design
High Frequency Transformers, Galvanically Isolated
Energy Management
Energy Management Analysis (EMA) system
Warranty
(5)
10 Years Standard ; 15 Years Optional
(1) Nominal voltage/frequency range can be extended beyond nominal if
required by the utility.
(2) Limits may vary. Refer to local requirements to define the number of
microinverters per branch in your area.
(3) The inverter may enter to power de-grade mode under poor ventilation and
heat dissipation installation environment.
(4) Recommend no more than 80 inverters register to one ECU for stable
communication.
(5) To be eligible for the warranty, APsystems microinverters need to be
monitored via the EMA portal. Please refer to our warranty T&Cs available on
apsystem.com.au
© All Rights Reserved
Specifications subject to change without notice
please ensure you are using the most recent update
found at web : apsystem.com.au