ECU-C Installation/User Manual
5
2.Interface Explanation
2.1 AC Input Port
The AC Input port connects power through the power line.If only single-phase
power is needed, the L1 must be connected.
L1
L2
L3
N
PE
Three Phase
Single Phase
×
×
The AC input power should be assembled with disconnector(e.g. when the
current is bigger than 1A, the disconnector should be operated).
2.2 DC Input Port
The DC Input port connects power through the 16V DC power line.
2.3 RJ45 Ethernet Network Port
The ECU-C allows the user to communicate with the EMA, or log in to the
ECU-C's local page in the absence of the wired LAN and WLAN, to set up the
system and view the system data via Ethernet network port.
Ethernet cable connection is recommended for stable communication.
2.4 RJ45 SignalOnly for Australia
The RJ45 Signal is designed for DRM0/5/6/7/8, it should be connected by RJ45
connector in the package otherwise the inverters will not work.
Please do not plug out the RJ45.
Figure 5