QS1 Installation/User Manual
16
7.Replace a microinverter
Follow the procedure to replace a failed APsystems Microinverter
A. Disconnect the APsystems Microinverter from the PV Module, in the order shown below:
1. Disconnect the AC by turning off the branch circuit breaker.
2. Disconnect the inverter AC connector from the AC Bus.
3. Disconnect the PV module DC wire connectors from the microinverter.
4. Remove the Microinverter from the PV array racking.
B. Install a replacement Microinverter to the rack. Remember to observe the flashing LED
light as soon as the new Microinverter is plugged into the DC cables.
C. Connect the AC cable of the replacement Microinverter and to the AC bus.
D. Close the branch circuit breaker, and verify operation of the replacement Microinverter.