EasyManua.ls Logo

APsystems YC600 - YC600 Microinverter Datasheet

APsystems YC600
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
APsystems YC600 Installation/User Manual
19
8.1 YC600 Microinverter Datasheet
Region
North America
Model
YC600
Input Data (DC)
Recommended PV Module Power (STC) Range
250Wp-340Wp / 60 and 72-cell PV modules
MPPT Voltage Range
22V-45V
Operation Voltage Range
16V-55V
Maximum Input Voltage
55V
Maximum Input Current
12A x 2
Maximum Input Short Circuit Current
13.2A
Output Data (AC)
Peak Output Power
600VA
600VA
Maximum Continous Output Power
548VA
548VA
Nominal Output Voltage
240V
208V
Nominal Output Current
2.28A
2.63A
Maximum Units Per Branch
7 (14 PV modules)
6 (12 PV modules)
Nominal Output Frequency
60Hz
60Hz
Adjustable Output Voltage Range
160-278V
Adjustable Output Frequency Range
55.1-64.9Hz
Power Factor
>0.99
Total Harmonic Distortion
<3%
Maximum Output Fault Current (AC) And Duration
170 Apk, 0.36 ms of duration
Maximum Output Overcurrent Protection
6.3A
Efficiency
Peak Efficiency
96.5%
Nominal MPPT Efficiency
99.5%
Night Power Consumption
60mW
Mechanical Data
Operating Ambient Temperature Range
-40
o
F to +149
o
F (-40 °C to +65 °C )
Storage Temperature Range
-40
o
F to +185
o
F (-40 °C to +85 °C )
Dimensions (W x H x D)
10.3” × 7.4” × 1.2” (260mm X 188mm X 31.5mm)
Weight
7.1lbs (3.22kg)
AC Bus Maximum Current
20A
Connector Type
MC4 Type or Customize
Enclosure Environmental Rating
NEMA6
Cooling
Natural Convection - No Fans
Overvoltage Category
OVC II For PV Input Circuit, OVC III For Mains Circuit
Utility Interconnection Voltage And Frequency Trip
Limits And Trip Times
See NOTE 1 Below
Trip Limit And Trip Time Accuracy
Voltage
+/-2V
Frequency
+/-0.1Hz
Alternate Trip times
See NOTE 1 Below
Features & Compliance
Communication (Inverter To ECU)
Zigbee
Transformer Design
High Frequency Transformers, Galvanically Isolated
Monitoring
Via EMA
*
Software
Safety And EMC Compliance
UL1741 FCC Part15; ANSI C63.4;ICES-003
Grid Connection Compliance
IEEE1547
Waranty
10 Years Standard ; 20 Years Optional