6. Technical parameter
Model
BS70
BS90
BS130
BS150
BS170
BS210
BS280
BS280S
BS350S
PERFORMANCE CONDITION: Air 27°C/ Water 27°C/ Humid. 80%
Heating
capacity(kW)
7.0
9.0
11.0
13.0
15.0
17.5
21.0
26.0
28.0
35.2
COP Range
14.0~7.5
14.0~7.5
14.0~7.0
14.5~7.2
15.0~7.0
15.6~7.0
14.8~7.1
16.0~7.3
15.8~7.3
15.5~7
PERFORMANCE CONDITION: Air 15°C/ Water 26°C/ Humid. 70%
Heating
capacity(kW)
5.0
6.6
7.7
9.0
10.5
12.5
14.5
19.0
19.0
24.2
COP Range
7.3~4.5
7.5~4.8
7.3~4.7
7.5~5.0
7.7~4.9
7.8~5.2
7.1~5.0
8.0~5.0
8.0~5.0
7.5~5.0
PERFORMANCE CONDITION: Air 35°C/ Water 28°C/ Humid. 80%
Cooling
capacity(kW)
3.5
4.4
6.3
7.4
8.0
10.1
11.9
11.9
16.1
TECHNICAL SPECIFICATION
Advised pool
volume (m
3
) *
15~30
20~45
30~55
35~65
40~70
40~80
50~95
60~120
60~120
85~160
Operating air
temperature
(℃)
-10℃~43℃
Power supply
230V 1Ph
400V 3Ph
Rated input
power (kW)
0.14~1.12
0.19~1.38
0.22~1.64
0.26~1.8
0.28~2.15
0.32~2.41
0.38~2.90
0.49~3.80
0.49~3.80
0.65~4.84
Rated input
current (A)
0.61~4.83
0.83~5.98
0.96~7.13
1.13~7.83
1.22~9.32
1.39~10.5
1.66~12.7
2.15~16.53
0.71~5.51
0.95~7.01
Sound level at
10m dB(A)
16.5~26.0
16.8~26.1
16.6~27.9
20.1~28.7
19.3~32
21.1~31.8
18.9~32.2
21.5~32.9
21.5~32.9
20.6~32.6
Advised water
flux (m³/h)
2~4
2~4
3~5
4~6
5~7
6~8
8~10
10~12
10~12
12~18
Water
connection
(mm)
50
Remarks:
This heat pump is able to perform normal within air temp -10℃~+43℃, efficiency will not be guaranteed
out of this range. Please take into consideration that the pool heater performance and parameters are
different under various conditions.
Related parameters are subject to adjustment periodically for technical improvement without further