OPERATION PARAMETER
IMPORTANT: The following conditions for feed water supply must
be met or warranty will be void and the manufacturer assumes no
responsibility for damage to system or property.
1. Water Temperature Parameter
The system MUST NOT be installed in an area where it is exposed to
direct sunlight and must be protected against freezing and extreme heat.
• Maximum: 100° F (37.8° C)
• Minimum: 32° F (0° C)
2. Water Pressure Parameter
The maximum allowable inlet water pressure is 125 psi. If daytime
pressure is over 80 psi, night time pressure may exceed the maximum
allowed water pressure. Use a pressure reducing valve (PRV) to reduce
the pressure if needed.
• Maximum: 125 PSI (8.78 kg/cm2)
• Minimum: 25 PSI (1.75 kg/cm2)
3. Water condion tolerance
Water passed through the unit must fall within the following parameters:
a) Iron: <0.3 ppm (0.3 mg/L)
b) Hardness*:<7 ppm (120 mg/L)
c) Turbidity: < 1 NTU
d) Manganese: < 0.05 ppm (0.05 mg/L)
e) Tannins: < 0.1 ppm (0.1 mg/L)
f) UV Transmittance: > 75% (call factory for recommendations on
applications where UVT < 75%)
* Where total hardness is more than 7 gpg, the water should be softened.