Troubleshooting
PROBLEM
Hose connector is dicult to connect or disconnect.
We stand behind every product we sell, and support
our customers even further. If you ever have an
issue, contact us and we will make it right.
Aquor oers a 10 year warranty on all stainless
steel components, and 5 years on all polymer
components. For more information, contact us or
visit our website at www.aquorwatersystems.com.
For any questions, please get in touch with our customer
service team at contact@aquorwatersystems.com or call
us at 1-800-458-1749.
Warranty Contact Us
SOLUTION
Try squeezing your hose nozzle while simultaneously
disconnecting.
If left outdoors in variable weather, water expansion
may have caused the connector’s internal check-valve
to seize. Try disassembling or removing the connector’s
check valve. Test with a dierent hose connector.
There may be a piece of debris stuck in the hydrant’s
main valve. Shut o the water supply, then test the valve’s
forward/back operation with your thumb or a tool. It
should operate smoothly. If needed, remove hydrant’s
operating rod by unscrewing the rear inlet.
If the issue occurs gradually over time, try cleaning the
hydrant’s outlet and lubricating the connector O-rings.