Flex ECO 6S/X MRX Instruction Manual
August 2017 v1.0
Page 16 of 34
4.1.4 Transmitter Start Function Settings
When transmitter goes into sleep mode the system is temporarily
deactivated (MAIN relays opened). Press the START button or any
pushbutton to wake up the system (MAIN relays closed).
4.1.5 Transmitter Inactivity Timer Settings
Set how long the system enters the sleep mode when the transmitter is not in use (pushbutton
not pressed). When transmitter goes into sleep mode the receiver MAIN relays are deactivated.
Dipswitch
Settings
Time
Dipswitch
Settings
Time
1
xxx000xxxx
1 minute
5
xxx100xxxx
10 minutes
2
xxx001xxxx
20 seconds
6
xxx101xxxx
30 minutes
3
xxx010xxxx
3 minutes
7
xxx110xxxx
60 minutes
4
xxx011xxxx
5 minutes
8
xxx111xxxx
Constant On
(sleep mode
disabled)
Dipswitch
Settings
Function
1
xxxxxxxxx0
START
Reactivation
2
xxxxxxxxx1
Any Button
Reactivation