Flex ECO 6S/X MRX Instruction Manual
August 2017 v1.0
Page 23 of 34
S2 DIP 6~10
ON DIP
ON DIP ON DIP
4.2.4 Other Dipswitch Settings
S2 Dip Position 6 Function
Dip set to “0” or down Reserved
Dip set to “1” or up
Reserved
S2 Dip Position 7 Function
Dip set to “0” or down Reserved
Dip set to “1” or up
Reserved
S2 Dip Position 8 Function
Dip set to “0” or down Normal
Dip set to “1” or up Display system firmware version
S2 Dip Position 9 Function
Dip set to “0” or down
Normal
Dip set to “1” or up
System testing (receiver MAIN relays disabled)
S2 Dip Position 10 Function
Dip set to “0” or down
Receiver-to-transmitter remote pairing
(pressing the Pairing button required)
Dip set to “1” or up
Receiver-to-transmitter remote pairing
(pressing the Pairing button not required)