ARCAIR N6000 Automatic System - User Manual

Default Icon
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Issue Date: October 1, 2007
Manual No: 89210000
Safety and Operating
Instructions
N6000
Automatic
System
English
Français
Español

Table of Contents

Questions and Answers

  • J
    John StephensSep 23, 2025
    Why is the arc erratic or uncontrollable on my ARCAIR Industrial Electrical?
    • B
      Brittany SchaeferSep 23, 2025
      If you're experiencing an erratic or uncontrollable arc with your ARCAIR Industrial Electrical equipment, the constant current (CC) constant potential (CP) toggle switch on the MCCB might be improperly set. You might be using improper torch operating conditions for the electrode size. Insufficient arc voltage due to the “drooping curve” characteristics of the “CP” power source could also be the issue.
  • T
    Timothy SmithAug 25, 2025
    What to do if the electrode will not feed or retract on my ARCAIR N6000 Automatic System?
    • E
      Edwin WagnerAug 25, 2025
      Several factors can prevent the electrode from feeding or retracting on your ARCAIR Industrial Electrical equipment. First, ensure the electrode is correctly inserted and makes optimal contact with the drive system. If the contact shoe surface is damaged due to arcing, repair it by sanding if the damage is minor; otherwise, replace the shoe. Other potential issues include a defective “Jog” switch or “Control Power” switch on the control panel, a faulty motor cable connection on the MCCB*, a defective MCCB*, or a defective electrode drive motor. Replace any defective components.
  • A
    Adam McdowellAug 25, 2025
    Why will the tractor not run with the switch in the 'ON' position on my ARCAIR N6000 Automatic System?
    • L
      Lisa JosephAug 26, 2025
      If the ARCAIR Industrial Electrical tractor won't run with the switch in the 'ON' position, verify that the engagement lever is engaged. Also, check for power continuity from the source to the tractor. Look for a tripped breaker on the tractor and reset it if necessary. Inspect the power cable for any breaks and repair or replace it. If these steps don't resolve the issue, the power switch or the motor itself might be defective, requiring replacement. Also consider checking the motor speed control and transformer.
  • L
    Lori CarsonAug 27, 2025
    Why is the contactor overheating on my ARCAIR N6000 Automatic System?
    • K
      Kayla TorresAug 27, 2025
      If your ARCAIR Industrial Electrical system's contactor is overheating and the overheat indicators are on, the filter might be clogged. Clean the filter thoroughly, replacing it if necessary. Also, check the fan operation; if it's not operating or not operating efficiently, replace it.
  • L
    Lisa CooperAug 27, 2025
    What causes the tractor to not run in auto mode on my ARCAIR N6000 Automatic System Industrial Electrical?
    • J
      Jonathan SmithAug 27, 2025
      If the ARCAIR Industrial Electrical tractor won't run in auto mode, check for voltage at the receptacle and repair if needed. Also, check if the breaker on the tractor has tripped and reset it if necessary. If the issue persists, the power switch, motor, motor speed control, or transformer might be defective and need replacement.
  • S
    Shirley MarshallSep 14, 2025
    Why is there no control of travel speed on my ARCAIR N6000 Automatic System Industrial Electrical?
    • A
      Aaron Hines MDSep 14, 2025
      If there is no control of travel speed on your ARCAIR Industrial Electrical equipment, the set screw on the potentiometer might be loose; tighten it. If that doesn't resolve the issue, the potentiometer or the motor speed control might be defective and need replacement.
  • L
    Lauren IbarraSep 12, 2025
    Why does the air solenoid energize but the contactor doesn't on my ARCAIR N6000 Automatic System Industrial Electrical?
    • J
      Jonathan WilsonSep 12, 2025
      If the ARCAIR Industrial Electrical system's air solenoid energizes but the contactor doesn't, the contactor coil might be open. Replace the contactor coil assembly. Alternatively, the rectifier bridge in the contactor unit could be defective; replace the rectifier bridge.
  • A
    aandersonSep 13, 2025
    What to do if the tractor is loose on the track of my ARCAIR Industrial Electrical?
    • M
      Madeline Fisher MDSep 13, 2025
      If the tractor is loose on the track of your ARCAIR Industrial Electrical equipment, the track section may be worn. You can reset the adjustable wheel legs. If that doesn't help, replace the track section. Alternatively, the adjustable wheel legs might be loose; reset and re-lock them.
  • A
    Allison BakerSep 4, 2025
    What to do if the fan does not run with the control panel 'ON' on my ARCAIR N6000 Automatic System?
    • A
      anthony44Sep 5, 2025
      If the ARCAIR Industrial Electrical system's fan doesn't run when the control panel is on, there might be a break in the interconnect cable linking the contactor to the controller; check and replace it if necessary. The fan itself could be defective and need replacement. Additionally, a defective transformer in the contactor might be the cause.
  • L
    Laura ElliottSep 2, 2025
    Why does the fuse for the carriage keep blowing on my ARCAIR Industrial Electrical?
    • T
      thompsonwilliamSep 2, 2025
      If the ARCAIR Industrial Electrical system's fuse for the carriage keeps blowing, it could be due to a defective motor speed control, which would need replacement. Alternatively, the motor itself might be defective and require replacement. Finally, an excessive load could be causing the fuse to blow; try reducing the load.

ARCAIR N6000 Automatic System Specifications

General IconGeneral
BrandARCAIR
ModelN6000 Automatic System
CategoryIndustrial Electrical
LanguageEnglish