Arctic Essentials Owners Manual
27
Series Techoo


f the oonator is not working,
follow this troubleshooting ow chart:
StepbyStep
Oonator doesnt work / ow chart stepbystep
as -PS[LY*`JSL
indicator
appeared stead
on epad
displa
yes
no
Start up a
filter cycle.
yes
Do ou read
 for a
 oonator
or  for 
 on
the board
no
yes
s Pump
oring
Replace spa pack
if you still aren’t
getting a voltage
reading.
no
Refer to Pump 1
does not Work!
section.
Flow chart
Ozonator output will be shut down when Pump 1, Pump 2 or blower have been turned on manually.
f the oonator is not
working:
Check if Filter Cycle
indicator appears
steady on keypad.
If the filter indicator
is blinking it indicates
that the filter cycle has
been interrupted.
In that case, reset the
breaker by turning the
power off and on again
to resume cycle.
If not, start up a
filter cycle (see
Programming Filter
Cycles section).

If you dont get a
voltage reading,
replace the accessory
fuse.
If changing the fuse
does not fix the
problem, replace the
spa pack.
If voltage is as it should
be, replace ozonator.
If ozonator does not
work even when filter
cycle indicator is on,
take voltage reading
on the corresponding
AMP connector:
Pin 1 Pin 3
our reading should
be:
240 for
a 240 pump
120 for a
120 pump
Pin
Pin 1
Ozonator fuse (F2)
Replace
ozonator
Check
wiring and
plugs.
Replace if
needed.