If a keypad doesn’t work:
erify keypad connections and try spare keypad.
Replace keypad if problem is corrected.
Replace pack if problem is not corrected.
eypad connector
Keypad doesnt seem to work stepbystep
FC trips
Warning
Total current output cannot exceed total current
input rating
There are different GFCI models used on
the market. See manufacturers instructions
that come with the GFCI for specific information.
Note that all illustrations are examples only.
From
electrical box
To spa
Ground
wire
Main electrical boxGFCI panel
The Series packs are equipped with a GFCI tripper
circuit in case an HL error occurs.
Find the GFCI tripper circuit (1) on
the board located behind the temperature
probe and remove the jumper.
Activate the GFCI and see if an error occurs. If HL
appears, follow the HL error troubleshooting
chart (in the Troubleshooting section).
If no error occurs, re-install the jumper.
If the GFCI trips again replace the pack.
If the GFCI is still tripping, the error doesn’t come
from the GFCI tripper circuit.
erify that the GFCI circuit is properly connected.
From
electrical box
To spa
mportant
connections:
eutral of
FC must be
connected to
neutral bus.
eutral from
spa must be
connected to
breaker.
If its not, reconnect it.
erify the spa pack wiring (make sure that the
neutral and the ground have not been inverted)
If the GFCI is properly connected but still tripping,
Unplug all outputs from the spa pack
(pumps, blower, heater, ozonator etc).
If it doesnt trip while all outputs are unplugged,
reconnect one output at a time until the GFCI
trips again.
Replace defective component.
GFCI (1)
5V[L!0UJVYYLJ[.-*0^PYPUNTH`SLHK[VHJVUKP[PVU^OLYL[OL.-*0TH`56;[YPW^OLUP[ZOV\SKJH\ZPUNLSLJ[YPJHSZOVJR
OHaHYK(SSLSLJ[YPJHSPUZ[HSSH[PVUZZOV\SKILKVULI`X\HSPÄLKWLYZVUULSVUS`
Keypad connector