When the ignition is turned off the BLAXTAIR® system will automatically shut
down (similar to a laptop). A delayed shutdown option is available and may
have been set up by the installation engineer.
Do not disconnect the power supply (e.g. battery isolator) of the vehicle until
the BLAXTAIR® system has shut down.
4.3 Maintenance operations
4.3.1 Starting the machine: verification of
detection
At the beginning of each working day, before starting working with a vehicle
equipped with BLAXTAIR®, the operator should check that the BLAXTAIR®
is operational. Below is a more detailed procedure to verify correct operation
during the usual periodic checks of the machine.
Before performing the test, the operator should ensure that all safety
conditions are fulfilled and that he/she won’t endanger anyone. With the
assistance of a second person, the driver should carry out the following
procedure:
• Park the vehicle in a flat open area, surrounded by barriers. Make
sure that the vehicle cannot move;
• Draw the detection area on the ground;
• Turn on the ignition without starting the engine;
• Wait until the camera view is displayed on the screen and its frame
(and LED if fitted) is green;
• Make sure that the vehicle cannot move then engage reverse gear,
or any other signal needed to enable detection;
• Ask the assistant to move across the detection zone. Check that
the system detects the pedestrian as soon as they are in the danger
area. The screen frame should turn red immediately and the alarm
should sound as long as they stay or move within the detection area;
• If the test fails, contact Blaxtair hotline.