4.8 Access code
An access code adjustable from 0000 to 9999 serves to protect the
meter and its setpoints from unauthorized programming, and to lock the
access to some functions.
0 0 0 0 Factory code
x x x x
0 to 5 Access to the display shifting
6 to 9 No access
0 to 5 Access to the display and the output simulations
6 to 9 No access
0 to 5 Access to the function “tare” (except for temperature inputs)
6 to 9 No access
0 to 5 Access to the quick entering of alarm setpoints
6 to 9 No access
p15
About
dIP10
n
°
A0123
ProG
07.00
0Pt10.
Ar---.
Err.
0000
CH.SUM
FC4E
Validation / vertical
move
type of the instrument
Submenu
number of the instrument
programme version
code of the ins-
talled options
error code in case of
error self-diagnosis
check sum of the flash
memory
X1 : - : No analog output
A : Analog output
X2 X3 : - - : No relay output
r- : Output 2 relays
XXXXX
1 2 3 4 5.
XXXXX
1 2 3 4 5.
P.CodE
OLd
no
Enter former
code
if code not valid
(old)
display during 2s.
and revert to the
measure display
New code registered, and revert to
the measure display
if code correct
(old)
Enter new code
Reminder: If no key is pressed during 1 min, the instrument will revert to
the measure display. On factory exit, the access code is 0000
.
NEU
4.9 Programming of a new access code
SIMUL
SIMUL
Value of the
display
if
M
Press Menu to
revert to the
measure
display.
4.10 Functions which can be reached from the main menu
4.10.1 Simulation of the display
(accessible according to the programmed access code and if
option relay outputs or analog output)
The display can be simulated with the meter in order to validate the con
-
figuration of the analog output and the relays in the installation.
Note: The instrument will no longer measure during the simulation. The
analog output and the relay outputs will react according to the entered
display.
If alarm messages have been programmed, they may appear during the
simulation.
Entering of a new
display value