EasyManua.ls Logo

Arfa 1018S - Connecting Saw to Power Source

Arfa 1018S
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
420 189 58
430 149 46
410,502 140 43
414 115 35
Stainless
Steel
431 95 29
440C 80 24
304,324 120 36
304L 115 35
347 110 33
316,316L 100 30
416 189 58
TELLTALE CHIPS
Chips are the best indicator of correct feed force. Monitor chip information and adjust
feed accordingly.
Thin or powdered chips – increase feed rate or reduce
band speed.
Burned heavy chips – reduce feed rate and/or band
speed.
Curly silvery and warm chips – optimum feed rate and
band speed.
7 CONNECTING SAW TO POWER SOURCE
The electrical rating of your band saw is either 230 volt, single phase or 400 volt, three
phase magnetic control.
Before connecting your machine to an electrical power system, be sure the motor rating
agrees with the electrical system it is to be connected to. We recommend that #14 wire,
fused with a 16 amp, dual element, time lag fuse, be used to supply power to all machines
regardless of their electrical rating.
Refer to the electrical wiring diagram supplied with your machine for instructions on how to
connect saw to power source.
- -
11