This appliance can be used for cooling, dehumidifying and ventilating.
When switching between modes, the fan continues to rotate but the compressor stops: the compressor will start after 3
minutes. This delay protects the compressor from potential damage.
Cooling, Fan, Heating* (*available only on IRO PLUS)
Dehumidifying
THE DISCHARGE TUBE MUST ALWAYS BE CONNECTED to the appliance: the only exception is when the
appliance is used solely for dehumidification, in which case it is advisable to let the appliance discharge directly
into the environment for maximum efficiency (consult the "Dehumidification Mode" paragraph).
Regularly clean the air filters beneath the easily removable rear grille to keep the air conditioner working efficiently.
OPERATING MODES
1. COOLING MODE (COOL)
The “Cool” LED on the control panel will turn on.
The temperature can be adjusted to between 16 °C and 31 °C.
In this mode, each time the ON/OFF button is pressed the unit switches off, the appliance saves the
temperature
setting and retains this setting when it is switched on again.
In this mode, the fan speed can be adjusted and the Timer and SLEEP functions can be set.
For more silent operation, run the fan at low speed.
2. HEATING MODE (HEAT)*
The “Heat” LED on the control panel will turn on.
The temperature can be adjusted to between 16 °C and 31 °C.
In this mode, each time the ON/OFF button is pressed the unit switches off, the appliance saves the
temperature
setting and retains this setting when it is switched on again.
In this mode, the fan speed can be adjusted and the Timer and SLEEP functions can be set.
For more silent operation, run the fan at low speed.
*Available only in IRO PLUS model.
3. DEHUMIDIFICATION MODE (DRY)
Press the MODE button to select the dehumidification mode.
The temperature is controlled by the electronic board and cannot be adjusted.
In this mode, each time the ON/OFF button is pressed the unit switches off, the appliance saves the settings
and
retains them when it is switched on again.
The fan speed is set to low and cannot be adjusted.
NOTE
The air conditioner does not cool the room when operating as a dehumidifier.
When the appliance is used as a dehumidifier, the flexible pipe must not be connected.
For maximum dehumidification efficiency, leave the rear discharge attachment free to discharge directly into
the environment.
The dehumidification mode is recommended during autumn and winter.
If used during summer, it is best to leave the flexible pipe attached so that the hot air is discharged towards
the outside rather than into the room.
During dehumidification, continuous drainage should be implemented (see the next chapter, “HOW TO ELIMINATE
CONDENSATE”).
4. VENTILATION MODE (FAN ONLY)
Press the MODE button until the Fan icon appears.
In this mode, the fan speed can be adjusted.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Argo IRO and is the answer not in the manual?

Argo IRO Specifications

General IconGeneral
TypeMonobloc mobile air conditioner
Cord length1.5 m
Noise level65 dB
Hose diameter150 mm
Number of speeds3
Remotely operatedYes
Airflow (high speed)24 m³/h
Cooling capacity (max)10000 BTU/h
Air conditioner functionsCooling
Cooling capacity in watts (nominal)2720 W
Heating capacity in watts (nominal)- W
Cooling energy efficiency (EER, W/W)2.6
Display typeLED
Product colorWhite
AC input voltage230 V
AC input frequency50 Hz
Energy efficiency scaleA+++ to D
Energy efficiency class (cooling)A
Energy efficiency class (heating)No
Hourly energy consumption (cooling)1.1 kWh
Hourly energy consumption (heating)- kWh
Weight and Dimensions IconWeight and Dimensions
Depth382 mm
Width470 mm
Height770 mm
Weight28000 g