EasyManuals Logo

Argo IRO User Manual

Argo IRO
17 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #15 background imageLoading...
Page #15 background image
V 01/19
32
COMPRESSOR PROTECTION
It takes 3 minutes before it starts when the unit is turned off, it can not be restarted before 3 minutes have elapsed since
the previous stop.
AUTOMATIC DEFROSTING
When it works in heating, there is a risk that the ice will form on the battery: in this case the air conditioner stop working, to
melt the ice and then starts again.
CARE AND MAINTENANCE
WARNING!
Prior to carrying out any cleaning or maintenance, unplug the unit from the power socket.
1. Cleaning the air filters
The air filter must be checked at least once every two weeks of operation. Operating with dirty or clogged filters will
decrease the effectiveness of the air conditioner and can cause serious problems.
To remove the filter, release the rear grille then slide out the filter by gently pulling it.
Use a vacuum cleaner to remove any dust. Should this not
be sufficient, wash the filter with lukewarm water and
neutral detergent (if necessary), rinse it with cold water
then leave it to dry naturally before putting it back in place.
After putting the filter back in place, close the grille and
resume use of the air conditioner.
2. Cleaning the casing.
Use a soft damp cloth to clean the outer surface of the air
conditioner.
Do not use excessively hot water, solvents, petrol or other
aggressive chemical compounds, talcum powder and
brushes: they may damage the surface or colour of the
casing.
Remove any stains using warm water with a little neutral
detergent.
Do not pour water onto the air conditioner to clean it: this
may damage the internal components or cause a short
circuit.
3. Storage.
When you do not envisage using the air conditioner for a long time, clean the filters before storing it away.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Argo IRO and is the answer not in the manual?

Argo IRO Specifications

General IconGeneral
TypeMonobloc mobile air conditioner
Cord length1.5 m
Noise level65 dB
Hose diameter150 mm
Number of speeds3
Remotely operatedYes
Airflow (high speed)24 m³/h
Cooling capacity (max)10000 BTU/h
Air conditioner functionsCooling
Cooling capacity in watts (nominal)2720 W
Heating capacity in watts (nominal)- W
Cooling energy efficiency (EER, W/W)2.6
Display typeLED
Product colorWhite
AC input voltage230 V
AC input frequency50 Hz
Energy efficiency scaleA+++ to D
Energy efficiency class (cooling)A
Energy efficiency class (heating)No
Hourly energy consumption (cooling)1.1 kWh
Hourly energy consumption (heating)- kWh
Weight and Dimensions IconWeight and Dimensions
Depth382 mm
Width470 mm
Height770 mm
Weight28000 g