Page 30
Aries Spas • User Manual
muchslowerpace.Youwillnotbeabletoseeorfeelthepullofits
bottomsuction,butwillbeabletoseethewaterreturningtothespavia
theCirculation&RecoveryJets
The Top Skimmer is not drawing everything in
This is normal and takes no action on your part.
Yourspa'sCirculatingPumpmovessmallvolumesofwateroverlong
periodsoftimeforefciency.Eventually,thesurfaceitemsaredrawn
intothelter.
Nothing works except Circulation Pump and Light
The system has been incorrectly wired and is only
receiving 110 power, instead of 220.
Callyourelectrician,orcallAriesServiceDepartmentforproperwir-
inginstructions.
Air Blower does not work
Air Blower Pump's automatic shut-off feature has kicked
in.
Thepumpisdesignedtoautomaticallyshutoffafter30minuteruntime
topreventoverheatingifusershouldforgettoturnoff.Waitaminute,
thenturnreactivateblower.
Air Blower Pump's Internal High Limit has been tripped.
Thepumphasbecomeoverheated.Theinternalswitchwillresetitself
aftertheunithascooledsufciently.Wait20minutesorsoandtryto
turnonagain.
When Air Blower is turned on, all equipment shuts off and won't
restart
Air Blower has gotten wet.
TheGFCIbreakerhastrippedbecauseofmoisture.Themostcommon
causesare:
1)overllingofthespa(orlargebatherload)causingwatertooverow
theP-trap.
2)Largeamountsofhumidityorrain,runofffromsprinklers,etc.
Tocorrecttheproblem,drainspawatertoappropriatelevel,ifneces-