Page 29
Aries Spas • User Manual
sidetemperatureisveryhot,youmighttryaddingsomeice,also.This
willhelpspeedtheprocessofcoolingthewater.
Jet Pump does not work
There is an air lock inside the Jet Pump system (this is a
common problem in in-deck installations, especially after
spa has been drained and relled).
Afterturningsystemoff,locatetheQuickCoupler(itisblackandhas
ridgestoaidingripping)closesttothepumpthatisnotoperating.
Loosenitbyturningcounterclockwiseuntilwaterstartsowingout.
Retightenandtrytooperatethesystemagain.
Can hear Jet Pump running, but water is not circulating
All jets are partially or fully closed.
Shutoffspaimmediately,otherwiseyourjetpumpmayoverheatand
possiblyburnout.Makesuretoopen3jetsatleast75%.Openbyturn-
ingtheirouterringcounterclockwise.
Knife Valves are partially or fully closed.
Shutoffspaimmediately,otherwiseyourJetPumpmayoverheatand
possiblyburnout.MakesuretoopenallKnifeValvescompletely.If
theyarelocked,rotatethehandleone-halfturnandthenpullup.
Jet Pump and/or Blower Pump shuts off after using awhile
Jet Pump and/or Blower Pump has been running for 30
minutes, and has automatically shut itself off.
Pushthe"Jet"and/or"Aux"button(s)andtheJetPumpand/orBlower
willrestartandrunforanadditional30minutes,beforeagainshutting
offautomatically.
One of the Bottom Suction Fittings in the footwell area isn't working
The suction is a suction for the circulating pump
Yourspashouldhave3ormoreBottomSuctions.Oneoftheseisused
toreturnwatertotheCirculatingPump,theothersreturnwatertothe
JetPumps.TheJetPumpsarelargepumpsthatmoveagreatdealof
waterandthepullfromtheirsuctionsisverynoticeable.TheCirculat-
ingPumpisverysmall(forenergyefciency)andmoveswaterata