31
commissioning
SETTING
REGULATING THE CENTRAL HEATING IGNITION DELAY
lower Wobbe index (15°C, 1013 mbar) (MJ/m3)
gas ow max/min (15°C, 1013
mbar)
(nat - m3/h) (GPL - kg/h)
Green Leds
Temperature indicator
TAC
= no led lit
● = lit
40 50 60 70 80 90 *
0 min
●
1 min
● ●
2 min
● ● ●
3 min
● ● ● ●
4 min
● ● ● ● ●
5 min
● ● ●
● ●
●
6 min
* This LED is red
Green Leds
Temperature indicator
Max adjustable power
and soft ignition
= no led lit
● = lit
40 50 60 70 80 90 *
0 to 39 %
●
40 to 49 %
● ●
50 to 59 %
● ● ●
60 to 69 %
● ● ● ●
70 to 79 %
● ● ● ● ●
80 to 89 %
● ● ●
● ●
●
90 to 99 %
* This LED is red
Adjust the central heating ignition delay
1. Push ON/OFF button for 10 seconds, the red reset led
blinks.
2. Pressing the RESET button, the green led blinks.
3. Adjusting with the CH knob (Temporisation 0, 1, 2, 3, 4, 5, 6
minutes see table).
90°40°
50°
60° 70°
80°
on/o
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
9
6
12
I
REGULATING THE MAXIMUM CENTRAL HEATING POWER & SOFT IGNITION
Regulate the maximum central heating power (between minimum and maximum) to adjust the central heating
power and the soft ignition :
Adjust the setting on the front panel
1. Push ON/OFF button for 10 seconds, the red reset led
blinks.
2. Adjusting with the CH knob the maximum CH power
between 0 and 99 % (see table).
3. Adjusting with the DHW knob the soft ignition between
0 to 99 % (see table). The percentage level is visualized by
the green led.
4. To store the new values of settings, it is enough to push
ON/OFF button.
90°40°
50°
60° 70°
80°
on/o
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
9
6
12
I
90°40°
50°
60° 70°
80°
on/o
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
9
6
12
I