30
commissioning
Electricity supply
- Check that the voltage and frequency of the
electricity supply correspond to the data shown
on the boiler data plate;
- Make sure that the earthing connection is
ecient.
First ignition
1. Make sure that:
- The gas valve is closed;
- The electrical connection has been properly
carried out. Make sure that the green/yellow
earthing wire is connected to an ecient
earthing system;
- Use a screwdriver to lift the cap on the automatic
air relief valve;
- Switch on the boiler (by pressing the ON/OFF
button), the green led 3 will illuminate indicating
that the boiler is ready to operate.
Turn the CH button 5 between min. and max
position. The pump will start and the burner will
attempt to light, after 7 seconds the boiler will
lock out because there is no gas; the red Led 8
illuminates.
- Bleed the air from the radiators;
- The ue should be suitable and free from any
obstructions;
2. Open the gas cock and check the connection
seals, including the boiler connection joints,
making sure that the meter does not detect any
passage of gas. Eliminate any leaks.
3. Unlock the boiler by pushing the reset button.
The burner will light, if the rst start fails repeat
the operation until the burner lights.