EasyManua.ls Logo

Ariston E-Combi 30 - Gas Valve

Ariston E-Combi 30
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
51
MAINTENANCE GUIDE
MAINTENANCE GUIDE: CLAS HE
4.5 GAS VALVE
GAS VALVE
Tools
Time
15 min
1
Replacement gas valves are
not factory set and will need to
be set up (see page 32)
Remove the combustion
assembly (see 4.3)
Twist the gas valve anti-clockwise to
disconnect it from the fan
Bayonet
connection
1. Venturi 4. Inlet test nipple
2. Gas valve 5. Offset adjustment
3. Solenoids 6. Throttle adjustment
Page. 22 of 24