MAINTENANCE GUIDE: CLAS HE
Condensate trap
Maintenance Interval: Annually
or after cleaning primary heat exchanger
How : Visual inspection / Clean as necessary /
Add water before replacing
Pump
Maintenance Interval: At the first ignition and annually
How: Check that the AAV is open /
Visual inspection / Clean as necessary
Page. 24 of 24
MAINTENANCE GUIDE: CLAS HE
5 ANNUAL MAINTENANCE
Plate heat exchanger
Maintenance Interval: As necessary
How: To measure specification of DHW performance.
By-pass & Safety valve
Maintenance Interval: Annually
How: Visual inspection / Clean as necessary
Central heating filter
Maintenance Interval: Annually
How: Visual inspection / Clean as necessary
Flow switch operation
Maintenance Interval: Annually
How: Visual inspection / Clean as necessary /
Check flow rate
Expansion vessel
Maintenance Interval: Annually
How: Check air pressure is at 1 bar (System drained)
Ignition & detection electrodes
Maintenance Interval: Annually
How: Visual inspection / Clean as necessary / Distance from the
burner / Ionisation current more than 1 µA
Burner
Maintenance Interval: Annually
How: Visual inspection / Clean as necessary
Fan
Maintenance Interval: Annually
How : Visual inspection / Clean as necessary
Primary Heat exchanger
Maintenance Interval: Annually
How : Visual inspection / Clean as necessary
Page. 23 of 24