50
MAINTENANCE GUIDE
MAINTENANCE GUIDE: CLAS HE
4.4 FAN
FAN
Tools
Time
15 min
1
Remove the three screws to free the
fan.
Remove the combustion
assembly (see 4.3)
Twist the gas valve anti-clockwise to
disengage it from the fan
1. Venturi
2. Gasket
3. Fan
Fan & mixer venturi according to the model
Power Fan Venturi diameter
24 KW
EBM RG 128 45 W Ø 17 mm
EBM RG 128 45 W Ø 21 mm
30 KW
EBM RG 128 45 W Ø 25 mm
38 KW
Page. 21 of 24