7
launam sresu
Appliance shut-off conditions
The appliance is protected from malfunctions by means
of internal checks performed by the electronic P.C.B.,
which stops the appliance from operating if necessary.
In the event of lockout, the red LED lights - see table
below.
To restore the system, switch ON/OFF the device.
Error code table
Red
L.E.D.
Description Checks to make
Fixed Battery exhausted Replace battery
Single
ash
No hot water
produced
The appliance
won’t start
- Ensure that the
gas isolation valve
is open
- Ensure that
the inlet water
isolation valve is
open
- Ensure the knob
is not in OFF
position
- Check/Replace
batteries
Double
ash
Switch OFF the appliance - turn the knob
to the OFF position, close the gas valve,
remove the batteries.
Contact a quali ed technician.
Three
ashes
Four
ashes
Five
ashes
If the appliance won’t start again or stops repeatedly,
once you’ve carried out the relevant checks, turn
the knob to the OFF position, close the gas valve,
remove the batteries and contact a quali ed
technician.
SHOULD THE ERROR NOT BE ELIMINATED, DO
NOT ACTIVATE THE APPLIANCE.
WARNING!!
NEVER TAMPER WITH OR DECOMMISSION THE
FLUE GAS SENSOR. THIS COULD AFFECT THE
PROPER OPERATION OF THE APPLIANCE.
POOR DRAUGHT CONDITIONS COULD
CAUSE EXHAUST GAS BACKFLOW INTO THE
INSTALLATION ROOM.
HAZARD OF CARBON MONOXIDE INTOXICATION
Anti-freeze protection
Should the appliance be installed where pipes are
subjected to freezing, it is recommended to empty it.
Proceed as indicated below:
- Turn the knob to OFF position to switch off the
appliance.
- Remove the batteries
- Close the cold water inlet isolation valve
- Open the DHW taps until both the appliance and
pipes are completely emptied.
To ll the appliance again, open the cold water inlet
isolation valve together with DHW taps until water ows
steadily from all taps.
Temporary Shut-Off due to defective ue gas
discharge
This device causes the applaince to shut down in the
event of an anomaly in the ue gas discharge.
The appliance shutdown is temporary.
After 12 minutes, the aplliance begins the ignition
procedure; if normal conditions have been restored, the
appliance operates as normal. If not, it shuts down and
the cycle is repeated.
WARNING
In the event of a malfunction or if repeated intervention
is required:
- switch the appliace off,
- close the gas valve,
- remove the batteries,
- contact the Technical Assistance Service or a quali ed
technician in order to repair the ue gas discharge
fault once the cause of the malfunction is detected.
Whenever maintenance work is performed on the
device, use original spare parts only and follow the
relative instructions carefully.
Maintenance
Schedule an annual maintenance check-up for the
appliance with a competent person.
Correct maintenance always results in
savings in the
cost of running the system.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ariston FAST EVO and is the answer not in the manual?

Ariston FAST EVO Specifications

General IconGeneral
Energy EfficiencyA
Voltage220-240 V
ColorWhite
DimensionsVaries by model
WeightVaries by model
InstallationWall mounted
PowerVaries by model
Frequency50Hz

Related product manuals