39
technical areaarea tecnica
INSERIMENTO CODICE D’ACCESSO 222
ruotare l’encoder per selezionare 234 e premere il tasto OK
MENU COMPLETO
0RETE
0. 2
RETE BUS
0. 2.
0 Rete Bus attuale Caldaia
Indicazione dispositivi connessi via BUS
0. 4
DISPLAY
0. 4.
0 Zona da impostare da dispay da 1 a 3 (nr) 1
0. 4.
2 Disattiva tasto
termoregolazione
0 = Tasto AUTO attivo
1 = Tasto AUTO
diasattivato
0
2 PARAMETRI CALDAIA
2. 0 IMPOSTAZIONI GENERALI
2. 0. 0 Impostazione temperatura
sanitario
da 60 a 36 (°C) 45
regolabile dati Tasti 2
2. 2 IMPOSTAZIONI GENERALI
2. 2. 0 Lenta Accensione da 0 a 100
60 %
Valore massimo 100%
Valore minimo 0%
2.2.0 Livello Lenta Accensione
Vedi Tabella riepilogativa gas
2. 2. 3 Termostato Pavimento\TA2 0 = Termostato
Pavimento
1 =Termostato
Ambiente2
0
2. 2. 4 Termoregolazione 0 = Assente
1 = Presente
0
E’ possibile attivare la termoregolazione premento il
tasto AUTO
2. 2. 5 Ritardo partenza in
riscaldamento
0= Disabilitato
1= 10 secondi
2= 90 secondi
3= 210 secondi
0
2. 2. 8 Versione Caldaia
GENUS PREMIUM EVO
NON MODIFICARE
da 0 a 5 0
Versione Caldaia
GENUS PREMIUM EVO
SYSTEM
ATTENZIONE!
Modi care da 1 a 2 in caso di
collegamento ad un bollitore
esterno con termostato.
da 0 a 5
0 = NON UTILIZZARE
1 = Accumulo Ext con
Sonda NTC
2 = Accumulo Ext con
Termostato
3 = NON UTILIZZARE
4 = NON UTILIZZARE
5 = NON UTILIZZARE
1
RISERVATO AL SAT Solo in caso di sostituzione della scheda
elettronica
2. 2. 9 Settaggio potenza nominale
caldaia
RISERVATO AL SAT Solo in caso di sostituzione della scheda
elettronica
SERVICE CODE
Rotate encoder clockwise to select code 234 and press O
K
COMPLETE MENU
0 NETWORK
0. 2
BUS
NETWORK
0. 2.
0 Network Presence Boiler
Indication of the devices connected via BUS.
0. 4 BOILER USER INTERFACE
0. 4. 0 Zone to be set by display
from 1 to 3 (nr) 1
0. 4. 2 Thermoregulation button
deactivation
0 = Enabled AUTO
button
1= Disabled AUTO
button
0
2 BOILER PARAMETERS
2. 0 GENERAL
2. 0. 0
DHW Setpoint Temperature from 36 to 60 (°C)
Setting by DHW button 2
2. 2 BOILER GENERAL SETTINGS
2. 2. 0 Soft ignition from 0 to 100
60 %
Maximum value 100%
Minimum value 0%
2.2.0 Soft ignition
see Table summarising changes
2. 2. 3 Under oor thermostat or
zone 2 ambient thermostat
selection
0 = Floor safety
thermostat
1 = Zone 2 ambient
thermostat
0
2. 2. 4 Termoregulation 0 = Absent
1 = Present
0
Termoregulation can be activated by pressing the
AUTO button.
2. 2. 5 Heating ignition delay 0 = Deactivated
1 = 10 seconds
2 = 90 seconds
3 = 210 seconds
0
2. 2. 8 Boiler version
GENUS PREMIUM EVO
- NOT TO MODIFY
from 0 to 5 0
Boiler version
GENUS PREMIUM EVO
SYSTEM
ATTENTION !
Modify from 1 to 2 only with
connection to an external
storage with thermostat ON/
OFF
from 0 to 5
0 = NOT USED
1 = storage with
NTC
2 = storage with
thermostat
3 = NOT USED
4 = NOT USED
5 = NOT USED
1
ONLY FOR SERVICE - To be used only in substitution P.C.B.
2. 2. 9 Set boiler heat power
ONLY FOR SERVICE - To be used only in substitution P.C.B.
menu
sotto-menu
parametro
descrizione range
impostazioni di
fabbrica
note
menu
sub-menu
parameter
description value
default
setings
notes