Planning and Installation manual VV600/VV602Plus16
5. INSTALLATION
5.1. General instructions for system components
The VV600Plus and VV602Plus seismic detectors have cast zinc housing, with the
outside dimensions of 101 x 81 x 28 mm, and a weight of 380 g.
By removing the screw holding the cover to the chassi gives access to:
• Mounting holes
• Terminal
• Sensitivity setting
• Mounting space for testtransmitter VT705P
• Tamper switch
5.2. Mounting directly onto a steel surface
In most cases it is advisable to mount the detector directly onto a steel surface
using the bolts provided and threaded holes which you will have to make.
For mounting the following tools are recommended:
• Mounting plate VM600P used as drill template.
• Electric drill hammer.
• Felt pen.
• High speed steel drill, diam. 3.3 mm (for M4 tap).
• High speed steel drill, diam. 4.2 mm (for M5 tap).
• High speed steel drill, diam. 10 mm.
• Tap M4 (to mount VV600Plus on steel surface).
• Oil to cool drill and tap.