6.3. Control and function test
Check the proper mounting of the detector, the VT705P and the cabling
around them
Check the proper wiring of the system, preferably against a wiring diagram.
Apply power to the detector.
Perform the following tests:
1. Press the front of the VT610P, hand tester against the protected surface at the
fringe of the expected coverage area. Press the button. A buzzing sound will
be heard. The generated frequency is similar to the frequency of a termic
lance attack. The VV600Plus should give an alarm within 30 seconds and the
VV602Plus within 45 seconds.
1
2
2. Knock firmly with a hammer around the detector with two-second intervals
between blows. After five blows, the VV600Plus shall alarm. To protect the
surface from damage it is advised to use a small aluminium plate between
hammer and surface. This test simulates the attack with hammer and chisel
and is only valid for VV600Plus.