Planning and Installation manual VV600/VV602Plus 25
6. CONNECTING THE DETECTOR
6.1. Cable requirements
The wiring of VV600Plus detectors requires the following cable layout:
Number of Leads
Features System common Per detector
Power 2
Alarm 2
Tamper 2
Test LED 1 1
Test in 1
6.2. Wiring the detector into the system
Bring the cable(s) to the detector, feed them through the cable inlet, cut them,
leaving approximately 10 cm of cable after the strain relief. Remove the wire
insulation with about 1 cm.
Wire the terminals according to wiring diagram below.
(Illustration A: Form-A relay. and illustration B: Form-C relay)