19
7528%/(6+227,1*
6.1 List of codes
The tables below describe the error messages that can
be generated as well as possible measures.
Code Description Measure
U1 Lime descaler low level Top up descaler agent.
U2 Process agent low level Top up process agent.
U3 Rinse-aid low level Top up rinse-aid
U7 Warning of high temperature for
goods
Let the goods cool down.
U9 Inactivity warning The machine has been inactive for 72 hours.
A program with an empty chamber must
be run before using the machine to clean goods.
H6 Start attempt with door open Close the door (the machine makes a new start
DWWHPSW,IWKHHUURUUHFXUVFRQWDFWDXWKRUL]HG
service personnel.
H7 Cannot lock door Acknowledge the error as described above. Close the
door correctly. Make a fresh start attempt. If the error
UHFXUVFRQWDFWDXWKRUL]HGVHUYLFHSHUVRQQHO
H8 Cannot unlock door Acknowledge the error as described on the previous
SDJH,IWKHHUURUUHFXUVFRQWDFWDXWKRUL]HGVHUYLFH
personnel.
F1 Temperature sensor error &RQWDFWDXWKRUL]HGVHUYLFHSHUVRQQHO
F4 Logic error in door, door locked but
not closed.
&RQWDFWDXWKRUL]HGVHUYLFHSHUVRQQHO
F7 Disinfection temperature not reached. &RQWDFWDXWKRUL]HGVHUYLFHSHUVRQQHO
F8 Door open/unlocked during process &RQWDFWDXWKRUL]HGVHUYLFHSHUVRQQHO
F9 Settings error (E2 error) &RQWDFWDXWKRUL]HGVHUYLFHSHUVRQQHO
F10 &RXOGQRW¿OOHPSW\WDQN &RQWDFWDXWKRUL]HGVHUYLFHSHUVRQQHO
F11 Leakage &RQWDFWDXWKRUL]HGVHUYLFHSHUVRQQHO
F13 Program error &RQWDFWDXWKRUL]HGVHUYLFHSHUVRQQHO
6.2 Types of codes
• Ux is an information code.
• Hx is a handling code.