Citadel Bed Frame System
Instructions for Use
...with people in mind
830.331 Rev A • 08/2016

Other manuals for Arjohuntleigh citadel

Questions and Answers

Summary

INTRODUCTION

Product Overview

Detailed diagram and list of bed components and their labels for identification.

CLINICAL APPLICATIONS

Intended Use and Contraindications

Specifies intended use, indications, and contraindications for patient use.

General Product Information and Precautions

Safe Working Load and Patient Weight Limits

Details the safe working load and maximum patient weight capacity of the bed.

INSTALLATION

Weighing System Preparation

Instructions for preparing the weighing system, including removing transport bolts.

Electricity Supply and Power Cord Management

Power Cord Safety and Storage

Guidelines for connecting, storing, and handling the power cord safely.

Electrical Connections and Terminals

Electrical Connections Overview

Details the various electrical connection points and terminals on the bed frame.

Nurse Call and RS232 Connectivity

Cable Connection Safety and Guidelines

Instructions and warnings for connecting nurse call and RS232 cables correctly.

Optional Features: Power Outlets and Skin IQ

Auxiliary Power Outlet and Skin IQ Cable Usage

Information on auxiliary power outlet and Skin IQ power cable.

Citadel Patient Therapy System Integration

Mattresses: Selection and Compatibility

Guidelines for selecting and using appropriate mattresses with the bed.

Mattress Clearance and SafeSet Safety Indicators

SafeSet Feature Overview

Explains the visual indicators for four safety-critical bed parameters.

Mattress Size Information and Valve Covers

Mattress Size Label and Valve Cover Instructions

Details indicated by the mattress size label and valve cover usage.

OPERATING INSTRUCTIONS: Accessory Mounting

Lifting Pole and Accessory Sockets

Details the locations of sockets for lifting poles and other accessories.

Drainage Rails and Bed Length Adjustment

Bed Length Adjustment Procedure

Instructions on how to adjust the bed's length for transport or patient needs.

Bed Extension Procedures

Extending the Bed Frame and Deck

Step-by-step guide on how to extend the bed frame and deck.

Bed Height Controls and Mobility

Brakes and Steering Operation

Explains the operation of bed brakes and steering casters.

Side Rail Operation and Brake Pedals

Side Rail Operation

Instructions on how to lower and raise the side rails for patient safety.

Head;Foot Boards and Restraint Use

Patient Restraint Usage Guidelines

Details on the proper use, compliance, and attachment of patient restraints.

Restraint Attachment and Under Bed Light

Under Bed Light Functionality

Information on the under bed light and its operation via the control panel.

Backup Battery Status and Operation

Battery Charge Level Indicators and Operation

Explains battery indicators and how the backup battery powers the bed.

Battery Recharge and Lockout

Over-Use Lockout and Battery Recharge

Describes the lockout function and battery recharge procedures.

Control Panel Functions Overview

Deck Height, Backrest Angle, and Indicators

Details controls for deck/backrest and explanations of key indicators.

Bed Section Controls and Safety Features

CPR Position and Function Lockout

Explains CPR function and how to lock/unlock bed controls.

Additional Bed Controls

Nurse Call and Auto-Chair Operations

Instructions for using nurse call and automated chair positioning.

Patient Handsets (Optional)

Handset Usage and Cable Management

Advice on using handsets and managing the handset cable.

Weigh Scale Panel Operation

Weighing System Buttons and Settings

Explains display, weigh, zero, units, and mute functions of the scale panel.

Weighing Accuracy Precautions

Factors Affecting Weighing Accuracy

Lists precautions to ensure accurate weighing system performance.

Weighing Initialization and Operation

Weighing Patients Weight Procedure

Detailed steps to calculate and display the patient's weight.

Weighing Units and Auto Compensation

Auto Compensation for Weight Adjustment

Explains how to add or remove weight without altering the indicated patient weight.

Weighing System Errors and Angle Indication

Weighing System Error Code Reference

Detailed table of weighing system error codes, their descriptions, and actions.

VariZone Patient Movement Detection

VariZone Controls and Sensitivity Adjustment

Explains VariZone controls and how to adjust detection sensitivity.

VariZone Operation and Thresholds

Activating and Adjusting VariZone Thresholds

Steps to activate and adjust the VariZone detection thresholds.

Anti-Entrapment System Safety

Anti-Entrapment Sensor and System Operation

Details the infrared sensors and how the anti-entrapment system functions.

SafeSet Safety Feature Overview

SafeSet Indicator Panel and Safety Parameter Overview

Explains the indicator panel and four safety parameters monitored by SafeSet.

SafeSet Indicator Light Control

Turning SafeSet Indicator Lights On;Off

How to turn the SafeSet indicator lights on or off using a key fob.

RS232 Connection and Data Transmission

Data Transmitted via RS232 Connection

Lists the type of data transmitted and its frequency via RS232.

Optional TV and Lighting Controls

TV and Lighting Control Button Functions

Details the function of each button for TV and lighting controls.

Patient Placement Procedures

Preparation for Patient Placement

Essential steps before placing patient, including bed setup and safety checks.

Patient Placement Completion

Final Patient Placement Configuration

Setting VariZone sensitivity, bed height, and locking functions.

Nursing Care and CPR Procedure

CPR Position Activation and Safety

Step-by-step guide to place the bed into the CPR position.

CPR Release and Patient Bathing

Patient Bathing Procedures and Precautions

Instructions for patient bathing, including safety and cleaning advice.

Patient Transfer and Transport

Patient Transport Guidelines and Safety

Guidelines for safely transporting the bed with a patient on board.

Care and Cleaning: Deck Sections and Decontamination

Deck Section Removal and Decontamination Procedures

Instructions for deck sections and guidelines for decontamination.

Cleaning and Disinfection Methods

Recommended Disinfection Solutions and Practices

Recommended methods and solutions for disinfecting the bed.

General Cleaning and Infection Control

Cleaning Bed During Use and Between Patients

Procedures for cleaning the bed during patient use and between patients.

Preventive Maintenance: Caregiver Checks

Caregiver Daily and Weekly Maintenance Checks

List of daily and weekly checks for caregivers to perform.

Maintenance: Battery Test and Calibration

Battery Test Procedure and System Calibration

Procedure to test the backup battery and calibrate the weighing system.

Troubleshooting: Common Issues

Troubleshooting Bed Functionality and Maneuverability

Possible causes and actions for inoperative functions or maneuverability issues.

Troubleshooting Patient Weight and Nurse Call Errors

Possible causes and actions for errors in patient weight and nurse call function.

Troubleshooting: Weighing System Errors

Weighing System Error Code Reference

Detailed table of weighing system error codes, their descriptions, and actions.

Troubleshooting: Fault Indications and Product Lifetime

Troubleshooting Fault Indicators on ACP

Explains fault indications on the Attendant Control Panel and potential causes.

EMC Information: Electromagnetic Emissions

Electromagnetic Emissions Guidance and Compliance

Details on electromagnetic emissions and guidance for the bed's use.

EMC Information: Immunity and Voltage Variations

Electromagnetic Immunity Guidance and Standards

Details on electromagnetic immunity and guidance for voltage variations.

EMC Information: RF Separation Distances

Recommended RF Separation Distances and Guidelines

Recommended separation distances for RF communications equipment.

Warranty and Service Information

Contacting ArjoHuntleigh for Service and Support

How to contact for service, maintenance, and spare parts.

Specifications: General, Electrical, and Dimensions

Specifications for Weighing System and Mattress Size

Specifies weighing system capacity and mattress size details.

Specifications: Mattress Size, Angles, and Storage

Transport and Storage Guidelines for the Bed

Guidelines for the safe transport and storage of the bed.

Questions and Contact Information

ArjoHuntleigh Global Contact Details

Provides contact details for ArjoHuntleigh offices worldwide for product support.

Arjohuntleigh citadel Specifications

General IconGeneral
Bed Height (Highest)81 cm (32 in)
Cardiac ChairYes
Bed Length (Extended)2340 mm
Bed Width1030 mm
Bed Height (Lowest)320 mm
Trendelenburg/Reverse Trendelenburg+/- 16 degrees
X-Ray CapabilityYes
TypeBariatric Bed
Maximum Weight Capacity250 kg
Lift Range500 mm
Power Supply120V AC, 60Hz
Width1030 mm
Length218 cm (86 in)
Wheel TypeLocking Casters