Do you have a question about the Arjohuntleigh Flowtron ACS800 and is the answer not in the manual?
It is the responsibility of the care giver to ensure that the user can use this product safely.
For your own safety and the safety of the equipment, always take the following precautions.
This product complies with the requirements of applicable EMC Standards.
Overview of the pump's control panel and LCD screen in Run Mode.
Description of the status indicated by the LED lights on the pump's front case.
This manual provides an introduction to the Flowtron ACS 800 system.
The intended use of this product is to prevent Deep Vein Thrombosis (DVT).
Description of the system's application and effects of pneumatic compression.
Diagram illustrating the front view of the Flowtron ACS 800 pump and its components.
Diagram illustrating the rear view of the Flowtron ACS 800 pump and its connections.
The primary application of the Flowtron ACS 800 system is for the prevention of Deep Vein Thrombosis (DVT).
Conditions where the Flowtron ACS 800 system should not be used with specific garments.
These instructions cover the day-to-day operation of the system.
Procedures for powering on the pump and initiating the diagnostic test.
Displays shown when the pump is in standby mode, with or without garments connected.
Steps to begin the patient therapy session using the pump.
Details the sequence and pressure for garment inflation and deflation during therapy.
Describes specific inflation cycles for foot and calf/thigh garments.
Procedure to stop the current therapy session and put the pump into standby mode.
Steps to safely power down the pump from standby mode.
Information on how the pump signals fault conditions with visual and audible alerts.
Procedures for modifying pump operating options like alarm volume and language.
Settings for the patient hours meter, including showing and clearing elapsed therapy time.
Procedure for selecting and changing the display language on the pump.
Information on how the pump is configured and limited adjustments available.
Recommended processes for cleaning the pump, including detergent and chemical disinfection.
Guidance on using chlorine-releasing agents or alcohol-based disinfectants.
Information on the maintenance-free design and servicing of the Flowtron ACS 800 system.
General care, inspection of connections, tubesets, and serial labels for the pump.
How the pump provides initial visual-only warnings for fault conditions.
How the pump provides audible and visual alarms for uncleared fault conditions.
Description and corrective action for low pressure warnings and alarms.
Description and action for faults related to blocked garments or kinked tubes.
Description and corrective action for when a garment is detected as removed.
Description and corrective action for low battery warnings and alarms.
Action to take when an internal hardware fault is detected by the pump.
Description and corrective action for faults detected in the tubesets.
Description and corrective action for faults related to incorrect setup or tubeset issues.
Understanding the 'spanner' icon indicating the need for service attention.
Description and corrective action for overheating warnings and alarms.
List of available calf garments with order codes and sizes.
List of available thigh garments with order codes and sizes.
List of available foot garments with order codes and shoe sizes.
Details on model, part numbers, pressure ranges, power, size, and weight.
Explanation of symbols used on the product and its electrical classifications.
Operating and storage conditions regarding temperature, humidity, and pressure.
Guidance on RF emissions and harmonic emissions for electromagnetic environment.
Guidance on conducted and radiated RF immunity and separation distances.
Recommended separation distances for portable and mobile RF communications equipment.
| Model | ACS800 |
|---|---|
| Category | Medical Equipment |
| Power Supply | 100-240V AC, 50/60 Hz |
| Operating Temperature | 10°C to 40°C |
| Intended Use | Prophylaxis of Deep Vein Thrombosis (DVT) |
| Application | Hospital, clinic, home care |
| Compression Mode | Sequential |
| Cycle Time | 12 seconds |
| Cuff Options | Foot Cuffs |
| Storage Temperature | -20°C to 60°C |
| Alarms | System Fault |
| Display | LCD |
| Portability | Portable |
| Safety Features | Automatic shut-off |