Do you have a question about the Arjohuntleigh Century and is the answer not in the manual?
Brand | Arjohuntleigh |
---|---|
Model | Century |
Category | Medical Equipment |
Language | English |
Explains the meaning of WARNING, CAUTION, NOTE, and manufacturer's name.
Criteria for assessing residents before using the bath.
Therapeutic uses for pain relief and tissue healing.
Requirements for installation and servicing by trained personnel.
The expected operational life of the Century bath.
Critical warnings to avoid injury, entrapment, electric shock, and cross-contamination.
Caution regarding the duration of Hydrosound system use.
Guidance on positioning the patient for safe bathing.
Requirements for the bath installation area, including floor finish and slope.
8 steps for initial setup and checks before the first use.
5 steps to perform before each use to ensure safety and hygiene.
Lists and identifies all parts of the Century bath system.
Specifies the electrical protection class and applied part type.
Describes the functions of buttons and displays on the control panel.
How to use the button to dispense shampoo or body wash.
Instructions for filling the bathtub using the auto fill function.
How to operate the patient shower function.
How to dispense bath oil or ArjoSound water conditioner.
How to start and stop the hydromassage or hydrosound system.
How to activate the disinfection unit.
Reading the water temperature in the bathtub.
Reading the water temperature for filling or shower.
How to operate the drain control knob to open or close the drain plug.
How to use the automatic bathtub filling feature.
How to use the shampoo, body wash, and conditioner dispensers.
Immediate action to take if scalding protection is activated.
Steps to reset the scalding protection system.
Step-by-step guide for using the patient shower.
Warning about checking water temperature before directing it onto the patient.
How to lock the shower trigger for continuous water flow.
Description of the built-in disinfection unit, its components, and operation.
Warning to install the suction cover to prevent hair entrapment.
Step-by-step guide for operating the built-in hydromassage jets.
How to adjust water flow and intensity using the knob.
How to adjust the direction of the water jets.
Note about stopping built-in jets before connecting the treatment hose.
Guide on connecting and using the treatment hose for localized hydromassage.
Warnings about avoiding burns and not using during pregnancy.
Step-by-step guide for operating the hydrosound system.
Caution against using other conditioners with the Hydrosound system.
How to select different intensity levels for the hydrosound system.
Warning to keep patient's head above water to prevent hearing damage.
Procedure for bathing the patient while the system is active.
How to rinse the patient after hydrosound treatment.
Detailed 14-step guide for transferring and bathing a patient.
Reiteration of warning to check water temperature before patient contact.
Warning to prevent entrapment of patient's body parts during movement.
Steps for positioning the lift hygiene chair correctly.
Warning about genital entrapment during lift chair movement.
Warning about entrapment of patient's or caregiver's legs/feet.
How to rotate the back rest for patient comfort.
Warning against leaving the patient unattended.
Steps for draining, drying, and moving the patient after bathing.
Information on using ArjoHuntleigh disinfectant for optimal performance.
Warning to follow instructions to prevent cross-contamination.
Warning not to disinfect in the presence of a patient to avoid irritation.
Description of the disinfectant spray handle and its location.
Safety precautions for handling disinfectants, use of PPE.
General advice for cleaning, using additives, and daily disinfection.
Caution against using specific substances that can damage the plastic surface.
Lists necessary accessories for cleaning and disinfection.
Precautions and practices to prevent bacterial growth and contamination.
Step-by-step guide for replacing the disinfectant bottle.
Table showing mix ratios for different disinfectants.
Steps for removing visible residue from the bath and accessories.
Detailed steps for cleaning the bathtub and accessories.
Caution against using abrasive materials that can scratch the surface.
Specific instruction for disinfecting the surface overflow outlet.
Warning to never use abrasive materials like Scotch-Brite or steel wool.
Instructions for scrubbing surfaces and rinsing to remove disinfectant.
Instructions for examining the bath and accessories after cleaning.
Comprehensive steps for disinfecting the bath system.
Note about skipping steps if the treatment hose is not present.
Note to check the flow meter for correct disinfectant mixture.
Steps for the automatic disinfection cycle of the hydromassage system.
Final steps for automatic disinfection and rinsing.
Note to continue with remaining disinfection instructions.
Warning to conduct regular inspections and follow the maintenance schedule.
Schedule of maintenance tasks for caregivers and qualified personnel.
Warning against modifying equipment or using incompatible parts during maintenance.
Requirements for cleaning and disinfecting between patient uses.
Daily tasks including checking liquid levels.
Weekly visual checks, hose inspection, and functionality tests.
Monthly tasks including shower head cleaning and filter checks.
Warning regarding pressurized system and scalding when removing filter caps.
Procedure for exercising the thermostat mixer.
Requirements for annual servicing and calibration by trained technicians.
Warning that maintenance must be done by qualified personnel with proper tools.
Note that caregiver obligations are checked during qualified personnel service.
Note to check power, water, and LEDs before troubleshooting.
Common issues and their corresponding troubleshooting actions.
Causes and solutions for fluctuating water temperatures.
Troubleshooting for maximum temperature being too hot or cold.
Solutions for when hydromassage or hydrosound functions stop.
Troubleshooting steps for when the water does not drain.
Solutions for water draining while the patient is bathing.
Troubleshooting when no foam builds up during disinfectant scrubbing.
Solutions for issues adjusting the disinfectant flow meter.
Troubleshooting for dispensers not dispensing shampoo, body wash, or conditioner.
Troubleshooting steps for main power failure.
Troubleshooting for failures in the temperature display read-out.
Warning to check water temperature manually due to display failure.
Troubleshooting for control panel buttons not reacting.
Troubleshooting for the disinfection function not starting.
Troubleshooting for hydromassage or hydrosound not starting.
Troubleshooting for flashing LEDs on disinfection and patient shower buttons.
Warning that flashing LEDs indicate activated scalding protection.
Technical data for the bath system including voltage, frequency, and power consumption.
Information on power supply, wiring, and pollution degree.
Specifications for the thermometer, including range, accuracy, and resolution.
Safe working load, maximum patient weight, and floor pressure ratings.
Minimum drainage capacity of the bathtub.
Maximum sound levels during hydromassage and bathtub filling.
Requirements for cold water, warm water, pressure, and flow rate.
Ambient temperature, humidity, and atmospheric pressure ranges.
Temperature, humidity, and atmospheric pressure for transport and storage.
Specifications for the permanently installed mains disconnection device.
Warning to only use allowed combinations as listed in the IFU.
Lists compatible ArjoHuntleigh lifts and upgrade kits.
Information on recycling packaging materials and bath components.
Information on proper disposal of the bath at end of life.
Warning regarding electrical connection safety, protective earth, and GFCI.
Explains the meaning of Identification, Data, and Water Connection labels.
Explains various symbols used on the device and in the manual.
Diagram illustrating the location of various labels on the bath.
List of plumbing standards and approvals the bath complies with.
List of electric and electromagnetic standards the bath complies with.
Warning about other electrical equipment interfering with the bath.
Warning that the equipment may cause radio interference.
Guidance on electromagnetic emissions and their environmental impact.
Guidance on electromagnetic immunity and environmental conditions.
Details of EMC immunity test levels and compliance.
Recommended minimum distance for RF equipment to avoid interference.
Catalog of available parts and accessories for the Century bath.
Contact addresses for ArjoHuntleigh in various countries.