ENTERPRISE 9000X (E9X)
...with people in mind
Instruction for Use
746-591-EN_12 • 12/2018

Other manuals for Arjohuntleigh ENTERPRISE 9000X

Questions and Answers

  • S
    Sara WoodAug 2, 2025
    Why is my Arjohuntleigh ENTERPRISE 9000X Medical Equipment bed beeping?
    • S
      sarah18Aug 3, 2025
      A beeping sound during bed use indicates the bed is running on backup battery power. Ensure the power cord is properly connected and the electrical supply is functioning correctly. Also, check the fuse in the mains plug, if applicable.
  • K
    Kevin WatkinsAug 7, 2025
    What to do if Arjohuntleigh ENTERPRISE 9000X shows errors in patient weight?
    • R
      Robert MyersAug 7, 2025
      If the indicated patient weight is inaccurate, check that the mattress platform is free from obstructions such as furniture, curtains, or cables. Also, verify that no weight has been added to the bed without using the auto-compensation function.
  • J
    Jonathan RossAug 12, 2025
    Why does Arjohuntleigh ENTERPRISE 9000X alarm sound when patient moves?
    • K
      Krista MartinezAug 12, 2025
      If the alarm sounds when the patient moves, the movement detection threshold might be set too low. Increase the VariZone threshold setting.
  • P
    Patricia MullenAug 17, 2025
    What to do if Arjohuntleigh Medical Equipment mattress platform cannot be lowered and shows error code AES?
    • A
      Ashley MurrayAug 17, 2025
      If the mattress platform cannot be lowered and the error code AES is displayed, the Anti-Entrapment system has been activated. Remove any obstructions from below the mattress platform. If the bed still cannot be lowered, contact an ArjoHuntleigh approved service engineer.
  • J
    Jeremy KellyAug 23, 2025
    Why is Arjohuntleigh Medical Equipment bed difficult to maneuver?
    • M
      Megan WallerAug 23, 2025
      If the bed is hard to maneuver, the brake pedals may be in the “steer” position. Place the brake pedals in the “free” position.
  • S
    stewartmarilynAug 28, 2025
    What does error code E300 mean on Arjohuntleigh Medical Equipment?
    • A
      Andrew HendersonAug 28, 2025
      Error code E300 indicates that a control button has been pressed for more than 90 seconds. Remove pressure from the control buttons. If the error code persists, contact an ArjoHuntleigh approved service engineer.

Summary

Warnings and Safety Notes

General Warnings

Critical safety warnings and precautions for using the bed.

2. Clinical Applications

Contraindications

Lists situations and conditions where the bed should not be used.

3. Installation

4. Operation

Brakes and Steering

How to use the bed's braking and steering castor system for mobility.

Split Side Rails

CPR Backrest Release

Mattress Platform Adjustment

Attendant Control Panel (ACP)

ACP CPR Position

Activating the CPR position via the Attendant Control Panel.

Function Lockout

Adjusting Calf Position

Backup Battery System

5. Advanced Features

Patient Weighing System

Controls and operation of the integrated patient weighing system.

Weighing System Initialization

Steps to initialize the weighing system before patient use.

VariZone Patient Movement Detection

Anti-Entrapment System

6. Product Care

Preventive Maintenance (Caregiver)

Preventive Maintenance (Qualified Personnel)

Yearly maintenance tasks for trained personnel and weighing system checks.

Backup Battery Test

Troubleshooting Guide

Fault Indications and Product Lifetime

10. Electromagnetic Compatibility (EMC)

Arjohuntleigh ENTERPRISE 9000X Specifications

General IconGeneral
BrandArjohuntleigh
ModelENTERPRISE 9000X
CategoryMedical Equipment
LanguageEnglish

Related product manuals