Display | LCD |
---|---|
Blood Sample | Capillary whole blood |
Sample Volume | 0.5 μL |
Measuring Time | 5 seconds |
Measurement Range | 20-600 mg/dL |
Measurement Method | Electrochemical |
Operating Conditions | 10-40°C, 10-90% RH |
Weight | 50 g |
Battery Life | Approximately 1000 tests |
Describes the intended purpose and applications of the GLUCOCARD Shine XL Blood Glucose Monitoring System.
Details technical specifications of the GLUCOCARD Shine XL Blood Glucose Monitoring System.
Specifies the environmental conditions for the meter's operation.
Outlines temperature and humidity requirements for storing and transporting the meter and test strips.
Lists the items included in the GLUCOCARD Shine XL Blood Glucose Monitoring System package.
Step-by-step guide on how to insert or replace the batteries in the GLUCOCARD Shine XL meter.
Describes the GLUCOCARD Shine XL Blood Glucose Test Strips and their absorption mechanism.
Identifies and describes the key components of the GLUCOCARD Shine XL Blood Glucose Meter.
Explains the meaning of various indicators, symbols, and messages shown on the meter display.
Guide on how to set and adjust the date and time on the GLUCOCARD Shine XL meter.
Instructions on how to enable or disable audible sound feedback for meter operations.
Step-by-step instructions for performing a control solution test using the GLUCOCARD Shine meter.
Compares test results to ranges and explains how to interpret control solution test outcomes.
Identifies common situations causing out-of-range control results and provides corrective actions.
Information on using the lancing device for blood sample collection.
Important safety precautions and usage notes for the lancing device to prevent infection and ensure proper use.
Step-by-step instructions for preparing the lancing device before collecting a blood sample.
Instructions on preparing the meter and inserting a test strip before testing.
Instructions on how to correctly insert a test strip into the GLUCOCARD Shine XL meter.
Instructions for obtaining a blood sample and applying it to the test strip for accurate measurement.
Provides safe procedures for removing and disposing of used lancets, including safety cautions.
Guide on how to attach or delete the post-meal flag for test results before sample application.
Instructions for obtaining a blood sample and applying it to the test strip for accurate measurement.
Describes how the test result is displayed, stored in memory, and how the meter powers off.
Explains Alternate Site Testing (AST) and its benefits for reducing pain during blood glucose monitoring.
Covers essential information, suitable situations, and requirements for fingertip testing versus AST.
Highlights crucial precautions, limitations, and advice for users performing Alternate Site Testing (AST).
Explains the 'HI' message indicating high blood glucose levels and recommended actions.
Explains the 'Lo' message indicating low blood glucose levels and recommended actions.
Provides normal blood glucose ranges and references for target blood glucose levels.
Information on transferring stored test results from the meter to a computer system.
Instructions on how to access and view previously recorded blood glucose test results and averages.
Guide for setting various alarms on the GLUCOCARD Shine XL meter.
Details on how to set and manage the post-meal alarm (PP2) on the GLUCOCARD Shine XL meter.
Guide to setting up to three time-based alarms on the GLUCOCARD Shine XL meter.
Instructions for cleaning and maintaining the GLUCOCARD Shine XL meter.
Provides essential guidelines for properly storing and handling the GLUCOCARD Shine XL system components.
Details on the 'Er1' error code, its cause, and resolution steps.
Details on the 'Er2' error code, its cause, and resolution steps.
Details on the 'Er3' error code, its cause, and resolution steps.
Details on the 'Er4' error code, its cause, and resolution steps.
Details on the 'Er5' error code, its cause, and resolution steps.
Details on the 'Er6' error code, its cause, and resolution steps.
Details on the 'Er8' error code, its cause, and resolution steps.
Provides troubleshooting steps for common issues like blank display or test failures.
Presents accuracy data for the GLUCOCARD Shine XL system evaluated in laboratory and clinical tests.
Details precision studies performed in a laboratory for the GLUCOCARD Shine XL Blood Glucose Monitoring System.
Compares test results from various Alternate Sites Testing (AST) sites with YSI measurements.
Outlines the manufacturer's warranty terms, conditions, and procedures for obtaining service.
Provides instructions and requirements for returning the GLUCOCARD Shine XL meter for service or warranty claims.