EasyManua.ls Logo

Arkray GLUCOCARD 01-mini User Manual

Arkray GLUCOCARD 01-mini
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
User
Instruction
Manual

Other manuals for Arkray GLUCOCARD 01-mini

Questions and Answers:

Arkray GLUCOCARD 01-mini Specifications

General IconGeneral
BrandArkray
ModelGLUCOCARD 01-mini
CategoryBlood Glucose Meter
LanguageEnglish

Summary

Introduction and Intended Use

Intended Use

Defines the purpose and target users of the GLUCOCARD™ 01-mini blood glucose monitoring system.

Understanding the GLUCOCARD™ 01-mini Meter

Display Screen Explanation

Details the symbols and indicators shown on the meter's display screen for various functions and statuses.

GLUCOCARD™ 01-SENSOR Test Strips

Changing the Battery

Provides instructions and precautions for replacing the meter's battery.

Changing Colored Faceplates

Step-by-step guide on how to detach and attach different colored faceplates to the meter.

Meter Set-up and Configuration

Basic Rules for Meter Set-up

Outlines the fundamental steps and rules to follow when performing the initial set-up of the glucose meter.

Setting the Audible Beep

Provides detailed instructions on adjusting the audible beep volume levels for the meter.

Setting Date and Time

Explains how to set the current year, month, day, hour, and minute for accurate record-keeping.

Setting Test Average Display

Describes how to choose and set the desired test averaging period (e.g., 7, 14, or 30 days).

Ending the Meter Set-up Process

Details the final steps to confirm and save all meter settings before turning it off.

Control Solution Testing Procedures

When to Perform a Control Solution Test

Lists the specific situations and conditions that require performing a control solution test.

Troubleshooting Control Solution Test

Provides guidance on diagnosing and resolving issues encountered during control solution testing.

Blood Glucose Testing Procedures

The Multi-Lancet Device

Introduces the Multi-Lancet Device and its components for obtaining blood samples.

Getting a Drop of Blood

Provides step-by-step instructions on how to properly obtain a blood drop for testing.

Performing a Blood Glucose Test

Guides users through the complete process of performing a blood glucose test with the meter.

Flagging Test Results

Explains how to use flags (pre-meal, post-meal, control, delete) to categorize and manage test results.

Alternate Site Testing (AST)

Alternate Site Testing (AST) Information

Provides important information and considerations regarding alternate site testing (AST) for blood glucose measurement.

When to Use Fingertip Testing

Details the specific circumstances and conditions where fingertip testing is recommended over alternate sites.

Preparing for Alternate Site Testing

Guides users on selecting and preparing the site for blood glucose testing using an alternate site.

Understanding and Interpreting Test Results

Comparing Meter and Lab Results

Provides guidelines on how to accurately compare blood glucose readings obtained from the meter with laboratory test results.

Normal Blood Glucose Readings

Presents expected blood glucose level ranges for adults without diabetes.

Low Blood Glucose Readings

Explains what constitutes low blood glucose readings and lists associated symptoms.

What Test Results Mean For You

Explains the significance of frequent blood glucose testing for diabetes management and treatment adjustments.

Frequency of Testing

Advises users to work with their healthcare professional to determine the optimal frequency for blood glucose testing.

Recalling Results and Memory Management

Recalling Results and Entering Memory Mode

Guides users on how to access and view stored blood glucose test results and averages from the meter's memory.

Deleting All Test Results

Provides instructions on how to erase all stored test results from the meter's memory.

Meter Maintenance and Care

Cleaning

Provides instructions on how to clean the blood glucose meter to ensure proper functioning and prevent damage.

Storage and Handling

Details the recommended conditions and practices for storing and handling the meter and test strips.

Display Screen and Error Message Interpretation

Battery and Temperature Errors

Explains error codes related to low battery power and out-of-range meter temperatures.

Test Strip and Code Errors

Describes error codes related to test strip issues, incorrect blood application, and code mismatches.

Product Information and Safety

Product Specifications

Lists the technical specifications of the GLUCOCARD™ 01-mini blood glucose meter and its components.

Warnings, Precautions, and Limitations

Details important warnings, precautions, and limitations associated with the use of the blood glucose meter.

Warranty and Returns

Covers warranty terms, conditions, and the process for returning the meter.

Related product manuals