All the tube sections are of similar stainless steel construction. The tube sections are
joined together with 'U’ shaped stainless steel pipes, connected to the heat exchanger
tube sections by hygienic tri-clamp stainless steel fittings. These fittings allow easy
access to the individual tube sections for inspection and cleaning.
Flexible hoses connect the heat exchanger to the hot and cold water systems. Again,
tri-clamp fittings are used for ease of changing the heat exchangers.
T1
T2
T3
Pressurised
Hot Water
Product Out
4 Coolin
Tubes
4 Heating Tubes
-
Product In
15