Maintenance and cleaning of the pellet insert
Before effecting any maintenance operation or cleaning on the pellet insert, take the following
precautions:
• be sure that all parts of the pellet insert are cold.
• be sure that the ashes are completely cold.
• be sure that the general switch is in the “OFF” position.
• be sure that the plug is pulled out of the socket to avoid accidental contact.
• once the maintenance phase is completed check that everything is in order as per before the intervention
(the brazier is placed correctly).
Follow carefully the following cleaning instructions. Failure to follow these
instructions could create problems with the operation of the pellet insert.
How to open the door of your replace insert
Open the door only when the fireplace insert is
switched off and cold. Use the provided dedicated
tool (detail 1, Pict. 7) to open the door: assemble
the hook at the one end of the detail 1 in the hole
of the handle and pull the door.
1
Pict. 7: opening door
Cleaning the brazier and brazier support
When the ame assumes a red colour or seems
weak, and is accompanied by black smoke, this
means that there are ash deposits or incrustations
that do not permit the correct functioning of the
pellet insert and that must be removed. Remove
the brazier every day by simply raising it from its
slot (Pict. 8); then clean out the ashes and eventual
incrustations that may have formed, paying par-
ticular attention to liberating the holes by using a
pointed tool (not included with the pellet insert).
This operation is made particularly necessary before
every lighting the rst several times and above all if
using pellets that differ from those supplied by our
company. The frequency of this operation is deter-
mined by how frequently the pellet insert is used
and the choice of pellets.
It is suggested to check the brazier support too. Re-
move it from its base and clean eventual ash rests
with an aspirator (Pict. 9).