Ascon Tecnologic - K Series - ENGINEERING MANUAL -Vr. 9.0 PAG. 35
]
con Group (Wattmeter - Consumption Parameters)
no.
Para-
meter
Description Dec. Range Default
Vis.
Promo.
126 co.ty Measurement type 0
oFF = Not used
1 = Instantaneous power (kW)
2 = Power consumption (kW/h)
3 = Energy used during program execution
4 = Total worked days with threshold
5 = Total worked hours with threshold
nonE A-97
127 UoLt Nominal voltage of the load 0 1... 999 (Volt) 230 A-98
128 cur Nominal current of the load 0 1... 999 (A) 10 A-99
129 h.Job Threshold of the worked hours/days 0 From 0 ( oFF) to 9999 oFF A-100
]
CAL Group (User Calibration Parameters)
no.
Para-
meter
Description Dec. Range Default
Vis.
Promo.
130 A.L.P Adjust low Point dP From -1999 to AH.P-10 (E.U.) 0 A-9
131 A.L.o Adjust low Offset dP -300... 300 (E.U.) 0 A-10
132 A.H.P Adjust High Point dP From A.L.P +10 to 9999 (E.U.) 9999 A-11
133 A.H.o Adjust High Offset dP -300... 300 (E.U.) 0 A-12