oFoF/ 0.01 ÷ 9.59
Output “ot” delay
P.P3
51
oFoF/ 0.01 ÷ 9.59
(min.sec ) ÷
99.5
(min.sec.x10)
Output “ot” delay after
switch off
50
oFoF/ 0.01 ÷ 9.59
(min.sec ) ÷
99.5
(min.sec.x10)
Output “ot” delay at
switch on
49
parameters relative to compressor protection and power
on delay
oFoF/ 0.01 ÷ 9.59
(min.sec ) ÷
99.5
(min.sec.x10)
Fan delay after defrost
48
oFoF - onFan status during
defrost
F.FE
47
1.00.0 ÷ 30.0
Differential fan control
F.dF
46
-99.9- 99.9 ÷ 999
°C/°F
Low temperature fan
deactivation
45
10.0- 99.9 ÷ 999
°C/°F
High temperature fan
deactivation
44
oFoF/ 0.01 ÷ 9.59
(min.sec ) ÷
99.5
(min.sec.x10)
with ot output
(compressor) off
43
5.00oF/ 0.01 ÷ 9.59
(min.sec ) ÷
99.5
(min.sec.x10)
with ot output
(compressor) off
42
parameters relative to evaporator fans control
10.0oF/ 0.01 ÷ 9.59
(min.sec ) ÷
99.5
(min.sec.x10)
Lengh of defrost cycle
for evaporator probe
error
41
6.00oF/ 0.01 ÷ 9.59
(hrs.min. ) ÷
99.5
Defrosting interval for
evaporator probe error
d.Ei
40
00 ÷ 100 %Dynamic Defrost
d.dd
39
6.00oF/ 0.01 ÷ 9.59
(hrs.min. ) ÷
99.5
Delay first defrost after
power-on
(oF = Defrost at
d.Sd
38
6.00oF/ 0.01 ÷ 9.59
(hrs.min. ) ÷
99.5
Defrosting interval
d.di
37
rtrt / ct / cSDefrosting starting
mode:
rt = real time intervals
ct = “ot” output on time
intervals
cS = defrost every “ot”
switching off (+ rt
intervals)
36
ELEL / in / no / EtDefrosting Type:
EL= Electrical
heating/stop. compr.
in= hot gas/reverse
cycle
no= without compr.
output condictioning
Et= Electrical heating
with evaporator tempe-
rature control
35
3oF / 1 / 2 / 3 Buzzer function mode
65
FnoF/ot/dF/Fn/Au/
At/AL/An/-t/-L/-
n/on/HE
OUT3 function:
see “o.o1”
o.o3
64
dFoF/ot/dF/Fn/Au/
At/AL/An/-t/-L/-
OUT2 function:
see “o.o1”
63
otoF/ot/dF/Fn/Au/
At/AL/An/-t/-L/-
n/on/HE
OUT1 function:
oF= No function
ot= Temperature
control (compressor)
dF= Defrosting
Fn= fan
Au= Auxiliary
At/-t= Silenceable
alarm
AL/-L= Not silenceable
Alarm
on= on when
instrument switch on
HE = Heating (Neutral
zone control)
o.o1
62
parameters relative to configuration of outputs and
buzzer
3.00oF/ 0.01 ÷ 9.59
(min.sec ) ÷
99.5
(min.sec.x10)
Alarm delay with door
open
61
1.00oF/ 0.01 ÷ 9.59
(hrs.min. ) ÷
99.5
(hrs.min.x10)
Temperature Alarms
delay after defrost and
continuous cycle, and
unlock display delay
after defrost
A.dA
60
2.00oF/ 0.01 ÷ 9.59
(hrs.min. ) ÷
99.5
Temperature Alarms
delay at power on
A.PA
59
oFoF - onAlarm memory
A.tA
58
oFoF/ 0.01 ÷ 9.59
(min.sec ) ÷
99.5
Temperature Alarms
delay
A.At
57
1.00.0 ÷ 30.0
°C/°F
Temperature Alarms
Differential
56
oFoF / -99.9 ÷
999 °C/°F
Low temperature
Alarm threshold
55
oFoF / -99.9 ÷
999 °C/°F
High temperature
Alarm threshold
54
11 / 2 / 3 / 4 / 5 /
6 / 7 / 8
Temperature alarms
Type:
1 = Pr1 absolute with
label (Hi - Lo)
2 = Pr1 Relative with
label (Hi - Lo)
3 = “Au” absolute with
label (Hi - Lo)
4 = “Au” Relative with
label (Hi - Lo)
5 = Pr1 absolute wit-
hout label
6 = Pr1 relative without
label
7 = “Au” absolute wit-
hout label
8 = “Au” relative wit-
hout label
53
parameters relative to alarms
oFoF/ 0.01 ÷ 9.59
(min.sec ) ÷
99.5
(min.sec.x10)
Delay outputs at power
on
52
99.5
ASCON TECNOLOGIC - Y33 - OPERATING INSTRUCTIONS - Vr. 01 - 04/16 - ISTR-MY33-ENG01 - PAG. 12