ascon G2 Series User Manual

ascon G2 Series
45 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #19 background imageLoading...
Page #19 background image
Value
Description
18
4 - Operation
Conf
EHit
Ht.f.C
Ht.on
bloc
éno
é100
éOFF
Output
Configuration
CT High range
(available if at least one
alarm is Htr)
10…100
CT decimal point
(available if at least one
alarm is Htr)
Off / On
Back
to operator mode
Back to the
1st parameter
AlM=Conf
Tab. 4
Value Description
0=5
0…5 Volt
1=5
1…5 Volt
0=20
0…20 mA
4=20
4…20 mA
Tab. 5 Control type
Of.re
Reverse action
On - Off
Of.di
Direct action
pid.d
Direct action
P.I.D.
pid.r
Reverse action
U.dir
Direct action
Modulating
valves
U.reU
Reverse action
H.C.ln
Linear
Heat/
Cool
H.C.Ol
Oil charac.
H.C.H2
Water charac.
Tab. 6 Heat control output
Value Description
éH.C.OP
Off
Not used
rI
Relay 1
Digital signal
log
SSR drive
0=5
0…5 Volt
Analogue
signal
1=5
1…5 Volt
0=10
0…10 Volt
0=20
0…20 mA
4=20
4…20 mA
Rem. Setpoint
Value Description
éOI.ty
Tab. 7 Cool control output
Value Description
ééC.C.OP
Off
not used
r2
relay 2
Digital signal
log
SSR drive
0=5
0…5 Volt
Analogue
signal
1=5
1…5 Volt
0=10
0…10 Volt
0=20
0…20 mA
4=20
4…20 mA
Tab. 8 Digital Inputs function
éIl1
Value
éIl2
Off
Not used
l=r
Local/remote
A.Man
Auto/manual
s.p.1
1st stored Setpoint
s.p.2
2nd stored Setpoint
keb.I
Keypad
slo.1
s.p. slope disable
H.pU
Measure hold
r.=H.
Run/stop of a program
Tab. 9 Alarm type
éAl1 éAl2
Off
Not used
fs.H
Active high
Absolute
fs.l
Active low
deU.H
Active high
Deviation
deU.l
Active low
band
Out active
Htr
Active high
lba
Loop break alarm (Al1 only)
Heater Break
Band
Tab. 1 Input type
éInp.
Value
Value
tc. j
0…600°C
Description
tc. l
éUnit
tc. K
tc. s
Tab. 2 Engineering units
none
None
°C
Centigrade Degrees
°f
Fahrenheit Degrees
MA
mA
MU
mV
U
Volt
bar
bar
psI
PSI
0=10
MU
tc. t
tc. r
rtd1
cuSt
1=5
0=5
rtd2
del.t
4=20
0=20
rh
Rh
ph
Ph
Tab. 3 Setpoint type
reM.t
Remote - trim
loc.t
Local - trim
l=r
Local/remote only
reM
Remote only
loc
Local only
Value Description
érs.p.C.
éAl3 éAl4
Description
Description
32…1112°F
4…20 mA
0…20 mA
0…10 Volt
1…5 Volt
0…5 Volt
0…50 mV
-50.0…50.0°C
-99.9...300.0°C
-200…600°C
Custom range on request
-200…400°C
0…1600°C
0…1600°C
0…1200°C
0…600°C
Engineering
units
-58.0…122.0°F
-99.9…572.0°F
-328…1112°F
-328…752°F
32…2912°F
32…2912°F
32…2192°F
32…1112°F
0=10
0…10 Volt
érs.In
Retransmission
éO.r.ty
M5 UK•ed4 10-12-2004 16:20 Pagina 18