Service manual DW90
21
Program flow description
Presented below is the Quick program, no options selected (DW90.1).
Programs and control unit
Explanations
Cleaning
process
*
Cleaning cycle for container 90 sec The circ. pump stops and the drain pump runs for 2 sec. The circ.
pump runs for 3 sec. and then rests for 5 sec. In total this is repeated
eight times, but the fifth time the circ. pump is resting for 8 sec instead
of 5 sec, when spray arm diverter is switching to the upper spray arm.
Inlet
process
**
Inlet process 255 sec A flow meter signals the flow in pulses. The control unit (CU)
determines how many pulses to be calculated for each inlet. If not 80
pulses has been reached within 60 sec or a specific number of pulses
is not reached within 255 sec, the program will be interrupted.
Drain
process
***
Drain process 120 sec The drain pump starts and pumps out until the level sensor reaches
a specified value. After that, the drain pump continues for additional
10 sec. The total time depends on how long it takes to reach the
specified value from the level sensor. If the specified value is not
reached within 120 sec, the program will be interrupted.
Step Component Time Comment
Main wash
1 Drain process 6 sec 12-16 sec when restarting or if an earlier program was interrupted
2 Inlet process 255 sec Maximum time. Inlet time is controlled by a flow meter**
3 Circ. pump 3 sec
4 Pause 30 sec If water temperature is >30°C ECO program starts (DW90.1)
5 Circ. pump 30 sec
6 Pause 5 sec
If ECO is
set
Circ.pump 120 sec
Drain process 120 sec Maximum time. Time is controlled by level sensor***
Inlet process 255 sec Maximum time. Inlet time is controlled by a flow meter**
7 Circ. pump + Combi dispenser 10 sec
8 Circ. pump + Element 60°C If ECO 30°C
9 Circ. pump 30 sec
10 Cleaning cycle for container 90 sec Maximum time 90 sec. Minimum time 76 sec*
11 Drain process 120 sec Maximum time. Time is controlled by level sensor***
1:st rinse
12 Inlet process 255 sec Maximum time. Inlet time is controlled by a flow meter**
13 Circ. pump 3 sec
14 Pause 5 sec
15 Circ. pump 3 sec
16 Drain process 120 sec Maximum time. Time is controlled by level sensor***
2:nd rinse
17 Inlet process 255 sec Maximum time. Inlet time is controlled by a flow meter**
18 Circ. pump 150 sec
19 Cleaning cycle for container 90 sec Maximum time 90 sec. Minimum time 76 sec*
20 Drain process 120 sec Maximum time. Time is controlled by level sensor***
3:rd rinse
21 Inlet process 255 sec Maximum time. Inlet time is controlled by a flow meter**
22 Circ. pump 60 sec
23 Circ. pump + Element 60°C
24 Circ. pump + Combi dispenser 10 sec Pulses (varies depending on the setting of rinse aid)
25 Drain process 120 sec Maximum time. Time is controlled by level sensor***
Drying
26 Fan 480 sec
27 Signal 4 sec If signal is selected