Service manual DW90
9
Components and measurement values
The specified resistance values apply at room temperature (about 20°C/68°F)
Values within ±10% are considered normal.
Component description
Article no. Position Component Measurement
value
8073779 EMC-filter with inductor 680 kohm
8083041 Filter with screwplint 1 Mohm
8079504 Heating element 1600 W 230 V 32 ohm
8079505 Heating element 1200 W 120 V 12 ohm
8078096 Thermistor 60 kohm
8083094 Combi disp. 230 V 1,32 kohm
8083095 Combi disp. 120 V 285 ohm
8078080
8078080
Circ.pump 220-240 V 50 Hz,
47 L (12.4 gallon)/min
Primary winding 115 ohm
Circ.pump 220-240 V 50 Hz Auxiliary winding 260 ohm
8078082
8078082
Circ.pump 120 V 60 Hz,
47 L (12.4 gallon)/min
Primary winding 31,4 ohm
Circ.pump 120 V 60 Hz Auxiliary winding 76 ohm
8078087 Drain pump 200-240 V 50 Hz,
16 L (4.2 gallon)/min
148 ohm
8078089 Drain pump 120V 60 Hz,
16 L (4.2 gallon)/min
26 ohm
8078084 2-3 Spray arm diverter 230 V 50/60 Hz 8,5 kohm
8078085 2-3 Spray arm diverter 120 V 60 Hz 2,6 kohm
8079502 Inlet valve single 200-240 V,
4 L (1 gallon)/min
3,9 kohm
8079503 Inlet valve single 120 V,
4 L (1 gallon)/min
0,95 kohm
8079500 Inlet valve security 220-240 V,
4 L (1 gallon)/min
2 kohm
8079501 Inlet valve security 120 V,
4 L (1 gallon)/min
0,5 kohm
8078090*
8078090*
Water softener salt valve 220-240 V 3 kohm
Water softener mix valve 220-240 V 2,33 kohm
8078302*
8078302*
Water softener salt valve 120 V 0,65 kohm
Water softener mix valve 120 V 0,65 kohm
8073830 Halogen lamp 5 W/12 V <10 kohm
8084147 Thermo Actuator 110-240 V 0,85-1,2 kohm
8089578 Fan motor 230 V 0,85 kohm
8089580 Fan motor 120 V 185 ohm
* The number is for a complete water softener; replacement salt and mixer valves are not available separately.