28
Set-up operation
Note
The installation and operation of electric locking devices on doors on
emergency exit routes are subject to building authority regulations. Com-
pliance must be ensured by both the fitter and the building operator.
Before the initial set-up operation:
Check all elements, including those which disengage the locking de-
vice and its electrical connections, to ensure they have been installed
and function according to regulations.
Have correct installation and operational capability of the escape door
locking device checked by technical specialists.
Install '
FT‑Manager
' software and check correct functioning (
1385
- networked only).
When the system is turned on or there is a failure in the power supply,
the position of the internal emergency switch and the status of all control
inputs are queried and evaluated. The resultant system switching status is
then directly dependent on these input parameters.
If an alarm is triggered after the system is switched on and the cause can-
not be immediately identified, the cause can be established by looking at
the LED colour combination on the escape door module (see table in the
'Alarm signals' section).
General
Switching on
or return of
power supply